Operation Manual
<6. PARAMETERS>
6-9
IM 01F06A00-01EN
(7) Item H : Adjust.
These items are for setting of adjustment.
A value in “( )” is the data corresponding to the indicator.
Item Name R / W Data Range Unit
Decimal
Point
Remark
Initial
Value
Disp. U / D
(*1)
H00 ADJUST Menu H (Adjust)
H10 TRIM 4mA W -1.00 to 1.00 % 2 Trimming 4mA 0.0 D
H11 TRIM 20mA W -1.00 to 1.00 % 2 Trimming 20mA 0.0 D
H20 USER ADJUST W 0.00001 to 32000 0 to 5 User Adjust 1.0 D
H25 REYNOLDS ADJ W NOT ACTIVE (0)
ACTIVE (1)
Reynolds Coeffi cient (0) D
(Indicate and Set only for H25: ACTIVE)
H26 DENSITY f W 0.00001 to 32000 D25 0 to 5 Density at operating condition 1024 D
H27 VISCOSITY W 0.00001 to 32000 mPa.s 0 to 5 Viscosity factor 1.0 D
H30 EXPANSION FA W NOT ACTIVE (0)
ACTIVE (1)
Expansion correction for
compressible Gas
(0) D
H40 FLOW ADJUST W NOT ACTIVE (0)
ACTIVE (1)
Instrumental Error Adjust (0) D
(Indicator and Set only for H40: ACTIVE)
H41 FREQUENCY 1 W 0 to 32000 Hz 0 to 5 First break-point frequency (f1) 0.0 D
H42 DATA 1 W -50.00 to 50.00 % 2 First correcting value (d1) 0.0 D
H43 FREQUENCY 2 W 0 to 32000 Hz 0 to 5 Second break-point frequency (f2) 0.0 D
H44 DATA 2 W -50.00 to 50.00 % 2 Second correcting value (d2) 0.0 D
H45 FREQUENCY 3 W 0 to 32000 Hz 0 to 5 Third break-point frequency (f3) 0.0 D
H46 DATA 3 W -50.00 to 50.00 % 2 Third correcting value (d3) 0.0 D
H47 FREQUENCY 4 W 0 to 32000 Hz 0 to 5 Fourth break-point frequency (f4) 0.0 D
H48 DATA 4 W -50.00 to 50.00 % 2 Fourth correcting value (d4) 0.0 D
H49 FREQUENCY 5 W 0 to 32000 Hz 0 to 5 Fifth break-point frequency (f5) 0.0 D
H50 DATA 5 W -50.00 to 50.00 % 2 Fifth correcting value (d5) 0.0 D
H60 SELF CHECK R GOOD
ERROR
Self-diagnostic message
(*1) : Available for 3.10 or greater version that can be checked in K50.
(8) Item J : Test
These items are for test of output.
A value in “( )” is the data corresponding to the indicator.
Item Name R / W Data Range Unit
Decimal
Point
Remark
Initial
Value
Disp.
U / D
(*1)
J00 TEST Menu J (Test)
J10 OUT ANALOG W 0.0 to 110.0 % 1 Current Output 0.0 D
J20 OUT PULSE W 0 to 10000 PPS 0 Pulse Output 0 D
J30 OUT STATUS W OFF (0)
ON (1)
Status Output (0) D
J40
(*2)
RELEASE TIME W 10min (0)
30min (1)
60min (2)
3h (3)
6h (4)
12h (5)
Test auto release time 0 D
J60 SELF CHECK R GOOD
ERROR
Self-diagnostic message
(*1) : Available for 3.10 or greater version that can be checked in K50.
(*2) : Available for 7.00 or greater version that can be checked in K50.