Operation Manual
<14. EXPLOSION PROTECTED TYPE INSTRUMENT>
14-9
IM 01F06A00-01EN
14.3 IECEx
WARNING
• Onlytrainedpersonsusethisinstrumentin
industriallocations.
• Electrostaticchargemaycauseanexplosion
hazard.
Avoidanyactionsthatcausethegeneration
ofelectrostaticcharge,suchasrubbingwith
adryclothoncoatingfaceofproduct.
(1) Technical Data
• Flameproof
ApplicableStandard:IEC60079-0:2007,
IEC60079-1:2007
Certicate:IECExDEK11.0077X
TypeofProtection:
ExdIICT6…T1Gb(IntegralTypeVortex
FlowmeterandRemoteTypeVortexFlow
Detector)
ExdIICT6Gb(RemoteTypeVortexFlow
Converter)
SpecicationofProtection:
ProcessTemperature:(IntegralTypeVortex
FlowmeterandRemote
TypeVortexFlow
Detector)
TemperatureClass ProcessTemperature
T6 -29°Cto+80°C
T5 -29°Cto+100°C
T4 -29°Cto+135°C
T3 -29°Cto+200°C
T2 -29°Cto+300°C
T1 -29°Cto+450°C
*1Note:Use/HTversionabove250°C
TemperatureClass:T6(RemoteTypeVortexFlow
Converter)
AmbientTemperature:
–29to+60°C(IntegralTypeVortexFlowmeter
andRemoteTypeVortexFlowDetector)
–40to+60°C(RemoteTypeVortexFlow
Converterwithoutindicator)
–30to+60°C(RemoteTypeVortexFlow
Converterwithindicator)
PowerSupply:10.5to42Vdcmax.
OutputSignal:CurrentOutput;4to20mAdc
Pulseoutput;On=2Vdc,200mA
Off=42Vdc,4mA
SpecialFastener:ClassA2-50ormore
• IntrinsicallySafe
ApplicableStandard: IEC60079-0:2011,
IEC60079-11:2011,
IEC60079-26:2006
Certicate:IECExDEK13.0066X
Typeofprotection:
ExiaIICT4…T1Ga(IntegralTypeVortex
Flowmeter)
ExiaIICT6…T1Ga(RemoteTypeVortexFlow
Detector)
ExiaIICT4Ga(RemoteTypeVortexFlow
Converter)
AmbientTemperature:
-29to+60°C(IntegralTypeVortexFlowmeter)
-40to+80[79]°C(RemoteTypeVortexFlow
Detector)
(Option/LTbelow-29°C,[]forOption/MVatT6)
-40to+80°C(RemoteTypeVortexFlow
Converterwithoutindicator)
-30to+80°C(RemoteTypeVortexFlow
Converterwithindicator)
(IntegralTypeVortexFlowmeter)
TemperatureClass ProcessTemperature
T4 -29°Cto+135°C
T3 -29°Cto+199°C
T2 -29°Cto+250°C
T1 -29°Cto+250°C
(RemoteTypeVortexFlowDetector)
TemperatureClass ProcessTemperature*
T6 -196°Cto+84/[+79]°C
T5 -196°Cto+100°C
T4 -196°Cto+135°C
T3 -196°Cto+199°C
T2 -196°Cto+299/[+289]°C
T1 -196°Cto+449/[+439]°C
*:Use/HToptionabove250°C,use/LToptionbelow-29°C,
[]for/MVoption.
Electricaldata:
SupplyandOutputCircuit
(SUPPLY+and-,PULSE+and-);
MaximumInputVoltageUi:30Vdc
MaximumInputCurrentIi:300mA
(RefertoContactratingforpulseoutput.)
MaximumInputPowerPi:0.9W
InternalCapacitanceCi:14nF
InternalInductanceLi:0mH
ElectricalConnection:ANSI1/2NPTfemale,
ISOM20X1.5female