Operation Manual
    <9. OPERATION VIA HART CONFIGURATION TOOL (HART 7)>
9-3
IM 01F06A00-01EN
9.6 Parameter Setting
The parameter structure of the HART confi guration 
tool is hierarchical.
Refer to Section 9.11 “Menu Tree (HART 7)” for the 
corresponding parameters. The menu tree shows 
a cross-reference of the parameters for HART 
confi guration Tool and BRAIN Terminal.
Refer to Section 6.4 “Parameters Description” for 
the functions of parameters.
Note that some display parameters of 
digitalYEWFLO are different from those of HART 
Confi guration Tools.
9.7  Data Renewing and Upload/
Download function
(1) Data renewing
  Following data are renewed in 0.5 to 2 seconds 
cycle.
    PV, PV%, rnge, Loop Current, Total
    Temp, TV% rnge, : only for /MV
(2) Upload/download function
  Upload/download parameters from 
digitalYEWFLO to the HART Confi guration 
Tool.
  Refer to Section 9.11 “Menu Tree (HART 7)” for 
the applicable parameters.
9.8 Self-Diagnostic
The self-diagnostic function of the digitalYEWFLO 
is explained in Section 6.5 “Self-Diagnostic (Error 
Code List)”.
The followings are additional items of the self-
diagnostic function.
• Burst confi guration error: Burst mode setting 
error.
•  Device variable simulation: Executing Device 
variable simulation function.
The HART confi guration tool is able to execute 
METHOD (*) of 'Self test/Status'. Confi rm the error. 
• Procedure to call up the Self test/Status;
[Root Menu]  Diag/Service  Self test/Status
(*) ‘Method’ is a program to faciliate the parameter settings.
9.9  Software Write Protect
digitalYEWFLO confi gured data is saved by using 
a write protect function. The write protect status is 
set to “Yes” when 8 alphanumeric characters are 
entered in the New password fi eld and transferred 
to the device. When write protect is set to “Yes,” 
the device does not accept parameter changes. 
When the same eight alphanumeric string entered 
in the New password fi eld is also entered in the 
Enable wrt 10min fi eld and transferred to the 
digitalYEWFLO, it will be possible to change device 
parameters during a 10 minute period.
To change the digitalYEWFLO from the write 
protect “Yes”status back to Write protect “No” 
status, use Enable wrt 10min to fi rst release the 
write protect function and then enter eight spaces in 
the New password fi eld.
9.10 Specifi c Functions of HART 
Confi guration Tool
9.10.1  Process Variable Setup (Dynamic 
Variables)
The device deals with four data (fl ow rate, 
temperature, density and total fl ow rate). In case of 
/MV, these four data are allocated to PV(Primary 
Variable), SV(Secondary Variable), TV(Tertiary 
Variable) and QV(Quaternary Variable). The 
variable of PV is 4 to 20mA current output. 
Therefore, the total fl ow rate do not allocate to PV. 
(Except /MV, each dynamic variables are fi xed at 
factory setting.)
Dynamic
Variable
Choice items
Factory 
Setting
PV Flow rate, Temperature Instantaneous 
Flowrate
SV
Flow rate, Total, Temperature, Density
Total Flowrate
TV
Flow rate, Total, Temperature, Density
Fluid
Temperature
QV
Flow rate, Total, Temperature, Density
Fluid Density
•  Procedure to call up the Dynamic variable 
assignments.
[Root Menu]  Detailed setup  Confi gure 
outputs  HART output  
Dynamic variable assignments ĺ PV is
ĺ SV is
ĺ TV is
ĺ QV is
ĺ Chng dyn var assign
 (METHOD)
F0905.ai