Operation Manual
    <8. OPERATION VIA HART CONFIGURATION TOOL (HART 5)>
8-2
IM 01F06A00-01EN
8.3  Setting Parameters using 
DTM
When confi gure the parameters using FieldMate, 
use the DTM (Device Type Manager) refering to the 
following table.
DTM Name Device Type
Device 
Revision
DYF V3.1 0 x 37 3
DYF V4.1 0 x 37 4
8.4 Interconnection between 
digitalYEWFLO and HART 
Confi guration Tool
The HART Confi guration Tool can interface with 
the digitalYEWFLO from the control room, the 
digitalYEWFLO site, or any other wiring termination 
point in the loop, provided there is a minimum load 
resistance of 250  between the connection and 
the receiving instrument. To communicate, it must 
be connected in parallel with the digitalYEWFLO, 
and the connections must be non-polarized. Figure 
8.2 illustrates the wiring connections for a direct 
interface at the digitalYEWFLO site. The HART 
Confi guration Tool can be used for remote access 
from any terminal strip as well.
+
–
4 to 20 mA DC signal line
Control room
Terminal board
Receiving instrument
load resistance:
 250  to 600 
Relaying
terminals
HART
Configuration Tool
HART
Configuration Tool
HART
Configuration Tool
F0803.ai
digitalYEWFLO
SUPPLY
SUPPLY
+
–
Figure 8.2  Connecting the HART Communicator
WARNING
Be sure to set parameters as “Protect” on the 
write protect function after fi nish of parameter 
setting work. Refer to Section 8.9 “Software 
Write Protect” how to use the write protect 
function in detail.
IMPORTANT
If the power of fl owmeter is turned off within 30 
seconds after parameters have been set, these 
settings will be canceled. Accordingly, please 
keep the power on for at least 30 seconds after 
setting parameters.
NOTE
Before updating any setting, remember to 
always check the data content you want to 
change as described in Section 6.4 “Parameters 
Description”.
8.5 Basic Setup
 Tag and Device Information
The tag number and device information can be 
checked as follows:
•  The location for the tag number and device 
information
Item Precedure
Tag [Root Menu]  Basic setup  Tag
Descriptor [Root Menu]  Detailed setup  
Device information  Descriptor
Message [Root Menu]  Detailed setup  
Device information  Message
Date [Root Menu]  Detailed setup  
Device information  Date
When changing the tag number or device 
information, enter the information directly within the 
following limitations.
Item Number and characters
Tag 8 
*1
Descripter 16 
*1
Message 32 
*1
Date 2/2/2 (mm/dd/yy)
•  mm : month
•  dd : day
•  yy : year
SPACE
 ! " # $ % & ' ( ) * + , - . /
 0   1   2  3   4   5   6   7   8   9  :  ;  <  =  >   ?
@  A  B C D E F G H  I  J K L M N O
 P Q R S T U V W X Y Z [ \ ] ^ _
F0804.ai
*1: All characters in the following table can be used.