Operation Manual
    <14. EXPLOSION PROTECTED TYPE INSTRUMENT>
14-15
IM 01F06A00-01EN
14.5 TIIS
Certifi cate:
Model 
Shedder 
bar 
Material 
Integral Type 
Flowmeter 
Remote 
Type 
Detector 
N (None 
Indicator) 
D (With 
Indicator) 
N (None 
Indicator) 
DY015 
DY025/R1 
DY040/R2 
E TC14901 TC14912 TC14923 
X TC18903 TC18914 TC18925 
DY025 
DY040/R1 
DY050/R2 
E TC19504 TC19513 TC19522 
X TC18904 TC18915 TC18926 
DY040 
DY050/R1 
DY080/R2 
E TC19505 TC19514 TC19523 
X TC18905 TC18916 TC18927 
DY050 
DY080/R1 
DY100/R2 
E TC19506 TC19515 TC19524 
X TC18906 TC18917 TC18928 
DY080 
DY100/R1 
DY150/R2 
E TC19507 TC19516 TC19525 
X TC18907 TC18918 TC18929 
DY100 
DY150/R1 
DY200/R2 
E TC19508 TC19517 TC19526 
X TC18908 TC18919 TC18930 
DY150 
DY200/R1 
E TC19509 TC19518 TC19527 
X TC18909 TC18920 TC18931 
DY200 
E TC19510 TC19519 TC19528 
X TC18910 TC18921 TC18932 
DY250  E  TC19511  TC19520  TC19529 
DY300 E TC19512 TC19521 TC19530 
DY400 B TC18945 TC18955 TC18965 
Model 
Shedder 
bar 
Material 
Remote Type 
Converter 
N (None 
Indicator)
D (With 
Indicator) 
DYA TC14934 TC14935
Integral Type Flowmeter  Remote Type Flowmeter 
None Indicator  With Indicator  Detector  Converter 
Construction 
Ex d IIC T6       
Flame Proof Approval       
Amb.Temp  -20°C up to 60°C       
Rating  Maximum power supply vortage: DC42V 
Current Signal: DC4-20mA 
Pulse Signal: 
ON : 2V 200mA 
OFF : 42V 4mA 
Output Voltage: 30Vp-p 
Output Current: 100 Ap-p 
Maximum power supply vortage: 
DC42V 
Current Signal: DC4-20mA 
Pulse Signal: 
ON : 2V 200mA 
OFF : 42V 4mA 
Input Signal: 30V p-p,100 A p-p 
Resistance Temp, Sensor Input: 
Pt1000 at 0°C 
Specifi ed Current: less than 1mA 
* In case that ambient temperature exceeds 50°C, use heat-resistant cables with maximum allowable temperature of 70°C or above.