Operation Manual
    <13. GENERAL SPECIFICATIONS>
13-17
IM 01F06A00-01EN
Table 13.10  Range of Measurable Saturated Steam Flow Rate at Selected Process Pressures
Model Code
Flow 
Rate 
Limits
Minimum and Maximum Measurable Flow Rate in kg/h 
0.1 MPa   0.2 MPa   0.4 MPa  0.6 MPa   0.8 MPa   1 MPa  
1.5 MPa  
2 MPa  
2.5 MPa  
3 MPa  
DY015  
DY025 
/R1 
DY040 
/R2 
min.  5.8(10.7)  7.0(11.1)  8.8(11.6)  10.4(12.1)  11.6(12.3)   12.8  15.3  19.1  23.6  28.1 
max.   55.8  80  129  177  225  272  390  508  628  748 
DY025  
DY040 
/R1 
DY050 
/R2 
min.  13.4(18.9)  16.2(20.0)   20.5  24.1  27.1  30  36  41  49  58 
max.   169.7  247.7  400  548  696  843  1209   1575  1945  2318 
DY040  
DY050 
/R1 
DY080 
/R2 
min.  26.5(29.2)   32  40.6  47.7  53.8  59  72  93  116  138 
max.   405  591  954  1310  1662  2012   2884  3759   4640  5532 
DY050  
DY080 
/R1 
DY100 
/R2 
min.   44.0  53  67.3  79  89  98  119  156  192  229 
max.   671  979  1580  2170  2753  3333   4778   6228  7688   9166  
DY080  
DY100 
/R1 
DY150 
/R2 
min.   84.9  103  130  152  171  189  231  300  371  442 
max.   1295  1891  3050  4188  5314  6435   9224   12024   14842   17694  
DY100  
DY150 
/R1 
DY200 
/R2 
min.   148  179  227  267  300  330  402  524  647  772 
max.   2261  3300  5326  7310  9276  11232   16102   20986   25907   30883  
DY150  
DY200 
/R1 
— 
min.   324  392  498  600  761  922  1322   1723  2127  2536 
max.   4950  7226  11661   16010  20315  24595   35258   45953   56729   67624  
DY200   —  — 
min.   697  841  1068  1252  1410  1649   2364   3081  3803   4534  
max.   8851  12918  20850   28627  36325  43976   63043   82165   101433  120913  
DY250   —  — 
min.   1256  1518  1929  2260  2546  2801   3655   4764  5882   7011 
max.   13687  19977  32243   44268  56172  68005   97489   127058  156854  186978  
DY300   —  — 
min.   1799  2174  2762  3236  3646  4012   5235   6823  8423   10041  
max.   19602  28609  46175   63397  80445  97390   139614  181960 
 224633  267772  
DY400 —  — 
min. 3381 4086 5187 6078 6848 8002 11472 14957 18468 22003
max. 32217 47070 75834 104152 132193 160037 229449 299131 369366 440055
(1) Maximum fl ow rate is the lower of 80m/s.
(2)  Minimum values are determined from Table 13.7. The values in parenthesis show the minimum linear fl ow rates (Re = 20,000 or 
40,000) when they are higher than the minimum measurable fl ow rate.