Operation Manual
    <11. MAINTENANCE>
11-8
IM 01F06A00-01EN
Where
 M : Mass fl ow
 Q
n
 :  Volumetric fl ow rate at standard condition
 Q
f
 :  Volumetric fl ow rate at oprtating condition
 T
n
 :  Temperature at operating condition (°C), 
(°F) 
 T
f
 :  Temperature at standard condition (°C), (°F)
 T
ft
  : Measured temperature value (°C), (°F)
 P
f
 :  Pressure at operating condition (kPa abs), 
(psi)
 P
n
 :  Pressure at standard condition (kpa abs), 
(psi)
 K : Deviation factor
  
ft
  : Density calculated by temperature value
  
n
  :  Density at standard condition (kg/m
3
), (lb/cf)
  
f
  : Density at operating condition
 U
pf
 :  Density unit conversion factor
 U
k(kg)
, U
k(Nm
3
)
, U
k(m
3
)
 : Flow rate unit conversion 
factor
 a
1
  : 1st temperature coeffi cient
 a
2
  : 2nd temperature coeffi cient
Example: conversion factor in kg.
 kg : U
k(kg)
 =1
 ton : U
k(kg)
 =0.001