User guide
6-11
IM DR231-11E
Commands
6
DIGITAL_PR Digital print
GR_TREND Trend recording in groups
MEMRY Store measured/computed
data on a RAM disk or
write them to DR.
FLOPY Store setup data on a
floppy disk or write them
to DR.
MATH Computation start/stop/
reset/clear/group reset
REPORT Report start/stop
FLAG Set flag to 1
p5 Auxiliary action information (for p3=EDGE)
• For p4=RECORD, selection of record start
or stop (ON, OFF)
• For p4=MSG_PR or MSG_DISP, message
number (01 to 20)
• For p4=GR_TREND, group number (G01
to G07)
• For p4=MEMRY
DATA_WR When the data retention
period is LOGIC, measured/
computed data are stored at
every measurement for each
event action.
WR_TRG Measured/computed data are
stored.
RD_TRG Measured/computed data are
read.
LD_TRG1 Setting data are read.
LD_TRG2 Setting data are read.
LD_TRG3 Setting data are read.
• For p4=FLOPY
LD_TRG1 Setting data are read.
LD_TRG2 Setting data are read.
LD_TRG3 Setting data are read.
• For p4=MATH
START Computation starts.
STOP Computation stops.
RESET Computed data are reset.
CLEAR Computed data are cleared.
RST_G01 to RST_G07:
Computed data in the
specified group are cleared.
• For p4=REPORT
START Report starts.
STOP Report stops.
• For p4=FLAG
F01 to F16: Specified flag number is set to
1.
p5 Auxiliary action information (for p3=LEVL)
• For p4=MEMRY
PAUSE Stops or restarts writing of
measured/computed data.
• For p4=FLAG
F01 to F16: Specified flag number is set to
1.
Event function setting by a remote, relay, timer,
manual function key or match time event
Setting SLp1, p2, p3, p4, p5, p6<terminator>
p1 Event action box number (01 to 30)
p2 Event (REMOTE, RELAY, TIMER,
MFUNC_KEY, MATCH_TIME)
p3 Auxiliary action information
• For p2=REMOTE, contact number (1 to 12)
• For p2=RELAY, relay number
• For p2=TIMER, timer number (1 to 6)
• For p2=MFUNC_KEY, MFUNC_KEY
number (1 or 2)
• For p2=MATCH_TIME, match time
number (1 to 3)
p4 Action mode (EDGE, LEVL)
p5 Action
ALARM_ACK Acknowledgement of alarm
status.
ALARM_RST Alarm reset
TIMER_RST Timer reset
RECORD Record start/stop
SPEED_CHG Change to second chart
speed
MSG_PR Message print
MANUAL_PR Manual print
MSG_DISP Display message
DIGITAL_PR Digital print
GR_TREND Trend recording in groups
MEMRY Store measured/computed
data on a RAM disk or
write them to DR.
FLOPY Store setup data on a
floppy disk or write them
to DR.
MATH Computation start/stop/
reset/clear/group reset
REPORT Report start/stop
FLAG Set flag to 1
p6 Auxiliary action information (for p4=EDGE)
• For p5=RECORD, record start/stop
selection (ON, OFF)
• For p5=MSG_PR, MSG_DISP, message
number (01 to 20)
• For p5=GR_TREND, group number (G01
to G07)
• For p5=MEMRY
DATA_WR When the data retention
period is LOGIC, measured/
computed data are stored at
every measurement for each
event action.
WR_TRG Measured/computed data are
stored.
RD_TRG Measured/computed data are
read.
LD_TRG1 Setting data are read.
LD_TRG2 Setting data are read.
LD_TRG3 Setting data are read.
• For p5=FLOPY
LD_TRG1 Setting data are read.
LD_TRG2 Setting data are read.
LD_TRG3 Setting data are read.
• For p5=MATH
START Computation starts.
STOP Computation stops.
RESET Computed data are reset.
CLEAR Computed data are cleared.
RST_G01 to RST_G07:
Computed data in the
specified group are cleared.
• For p5=REPORT
START Report starts.
STOP Report stops.
• For p5=FLAG
F01 to F06: Specified flag number is set to
1.
p6 Auxiliary action information (for p4=LEVEL)
• For p5=GR_TREND, group number (G01
to G07)
• For p5=FLAG
F01 to F16: Specified flag number is set to
1.
Example Set an event action to record message number 04
when the chart ends in event action box 02.
SL02, CHART_END, EDGE, MSG_PR, 04
Comments • With an action as the start (event), another action
(action) can be executed automatically.
• Thirty types of event actions can be set.
• If the action mode is EDGE, the set action
continues even if the event action is over.
6.5 Other Settings