Instruction Manual

Table Of Contents
IM 12A00A01-61E
Foundation Fieldbus 3-17
3-17
Realtive
Index
Parameters
Mnemonic
View
1
View
2
View
3
View
4
30 XD_MAN_ID[32]
31 TEMPERATURE_
COEFF
4
32 CONCENTRATION 5 5
33 TERTIARY_VALUE 5 5
34 REFERENCE_
TEMPERATURE
4
35 COMP_METHOD 1 1
36 COMP_MATRIX_SEL 1
37 TERTIARY_COMP_
METHOD
1
38 TERT_TEMPERATURE_
COEFF
4
39 ALARM_SUM 8 8
40 DEV_ALARM 4 4
41 LOGBOOK1_RESET
42 LOGBOOK1_EVENT
43 LOGBOOK2_RESET
44 LOGBOOK2_EVENT
45 LOGBOOK_CONFIG[16] 16
46 TEST_1
58 TEST_13
59 CALIB_SENSOR_
CONST
4
60 MATRIX_TEMP_RANGE
61 SOLUTION_1
62 SOLUTION_2
63 SOLUTION_3
64 SOLUTION_4
65 SOLUTION_5
66 CONCENTRATION_
MEASUREMENT
1
67 CONCENTRATION_0
68 CONCENTRATION_100
69
CONCENTRATION_
TABLE_LOW
70
CONCENTRATION_
TABLE_MID
71
CONCENTRATION_
TABLE_HIGH
72 E5_LIMIT 4
73 E6_LIMIT 4
74 DISPLAY_RESOLUTION 1
75 PASSCODE_
MAINTENANCE
2
76 PASSCODE_
COMMISSIONING
2
77 PASSCODE_SERVICE 2
78 ERROR_CONFIG 4
79 CONFIGURATION 4
80 TRANSMITTER_TIME 6
81 SOFTDWN_TEST 1
TOTALS (# BYTES) 43 17 54 96
Table 3.17 View Object for Transducer Block DO202
Realtive
Index
Parameters
Mnemonic
View
1
View
2
View
3
View
4
0 BLK_DATA
1 ST_REV 2 2 2 2
2 TAG_DESC[32]
3 STRATEGY 2
4 ALERT_KEY 1
5 MODE_BLK 4 4
6 BLOCK_ERR 2 2
7 UPDATE_EVT
8 BLOCK_ALM
Realtive
Index
Parameters
Mnemonic
View
1
View
2
View
3
View
4
9 TRANSDUCER_
DIRECTORY[2]
10 TRANSDUCER_TYPE 2 2 2 2
11 XD_ERROR 1 1
12 COLLECTION_
DIRECTORY[7]
13
PRIMARY_VALUE_TYPE
2
14 PRIMARY_VALUE 5 5
15 PRIMARY_VALUE_
RANGE
11
16
PRIMARY_VALUE_UNIT
2
17
SENSOR_TYPE_OXYGEN
2
18 SAMPLE_CAL
19 ZERO_CURRENT 4
20 SENSITIVITY 4
21
AMP_STABILIZE_TIME
4
22 AMP_SPAN_
STABILIZE _VALUE
4
23 AMP_ZERO_
STABILIZE_VALUE
4
24 SALINITY 4
25 BAR_PRESSURE 4
26
BAR_PRESSURE_UNIT
2
27
PERCENT_SATURATION_
PRESSURE
4
28
CHLORINE_
CALIBRATION_RANGES
29 SECONDARY_VALUE 5 5
30 SECONDARY_
VALUE_UNIT
2
31
SENSOR_TEMP_COMP
1
32 SENSOR_TEMP_
MAN_VALUE
4
33
SENSOR_TYPE_TEMP
2
34 TEMP_SENSOR_CAL 4
35 SENSOR_CURRENT 5 5
36
PERCENT_SATURATION
5 5
37
ZERO_CURRENT_LIMIT
4
38 ZERO_CAL
39 RESERVED1
40 RESERVED2
41 RESERVED3
42
TRANSMITTER_TIME[6]
6
43 PASSCODE_
MAINTENANCE
44 PASSCODE_
COMMISSIONING
45 PASSCODE_SERVICE
46 LOGBOOK1_RESET
47 LOGBOOK1_EVENT
48 LOGBOOK2_RESET
49 LOGBOOK2_EVENT
50
LOGBOOK_CONFIG[25]
25
51 CALL_MAINT_TIME_
RELOAD
1
52 CALL_MAINT_TIME_
COUNTDOWN
1
53 ERROR_CONFIG 4
54 CONFIGURATION 4
55 ALARM_SUM 8 8
56 DEV_ALARM 4 4
57 TEST_1
69 TEST_13
70 SOFTDWN_TEST 1
TOTALS (# BYTES) 43 12 50 102
Table 3.16 View Object for Transducer Block SC202/ISC202
(contineous)
Table 3.17 View Object for Transducer Block DO202
(continues)