3-16 Foundation Fieldbus
Relative
Index
PARAMETER NAME VIEW
_1
VIEW
_2
VIEW
_3
VIEW
_4
0 BLOCK HEADER
1 ST_REV 2 2 2 2
2 TAG_DESC
3 STRATEGY 2
4 ALERT_KEY 1
5 MODE_BLK 4 4
6 BLOCK_ERR 2 2
7 UPDATE_EVT
8 BLOCK_ALM
9 TRANSDUCER_
DIRECTORY
10
TRANSDUCER_TYPE
2 2 2 2
11 XD_ERROR 1 1
12 COLLECTION_
DIRECTORY
13
PRIMARY_VALUE_TYPE
2
14 PRIMARY_VALUE 5 5
15
PRIMARY_VALUE_
RANGE
11
16 SENSOR_TYPE_PH
17 SENSOR_MV
18 CAL_POINT_HI 4
19 CAL_POINT_LO 4
20 CAL_MIN_SPAN 4
21 SLOPE 4
22 SLOPE_UNIT 2
23 ZERO 4
24 ZERO_UNIT 2
25 ISOPOTENTIAL_PH 4
26
SENSOR_CAL_METHOD
1
27 SENSOR_CAL_DATE 8
28
SECONDARY_VALUE
5 5
29 SECONDARY_
VALUE_UNIT
2
30
SENSOR_TEMP_COMP
1
31 SENSOR_TEMP_
MAN_VALUE
4
32
SENSOR_TYPE_TEMP
2
33 SENSOR_
CONNECTION_TEMP
1
34
TERTIARY_VALUE_TYPE
2
35 TERTIARY_VALUE 5 5
36 TERTIARY_VALUE_
RANGE
11
37 TERTIARY_ZERO 4
38 GLASS_IMPEDANCE 4
39 REFERENCE_
IMPEDANCE
4
40 ALARM_SUM 8 8
41 DEV_ALARM 4 4
42 LOGBOOK1_RESET
43 LOGBOOK1_EVENT
44 LOGBOOK2_RESET
45 LOGBOOK2_EVENT
46 LOGBOOK_CONFIG 23
47 TEST_1
48-59 TEST_2 ... TEST_13
60 STABLE_TIME
61 STABLE_VALUE
62 CALL_MAINT_TIME_
COUNTD.
1
63 CALL_MAINT_TIME_
RELOAD
1
64 INPUT_1_
IMPEDANCE_LO_LIM
4
65 INPUT_1_
IMPEDANCE_HI_LIM
4
Relative
Index
PARAMETER NAME VIEW
_1
VIEW
_2
VIEW
_3
VIEW
_4
66 INPUT_2_
IMPEDANCE_LO_LIM
4
67 INPUT_2_
IMPEDANCE_HI_LIM
4
68 BUFFER1_ID
69 BUFFER1
70 BUFFER2_ID
71 BUFFER2
72 BUFFER3_ID
73 BUFFER3
74 TEMPERATURE_
COEFFICIENT
75 PASSCODE_
MAINTENANCE
76 PASSCODE_
COMMISSIONING
77 PASSCODE_SERVICE
78 SAMPLE_PV 4
79 SAMPLE_PV2 4
80 SAMPLE_TEMP 4
81 ERROR_CONFIG 4
82 CONFIGURATION 4
83 TRANSMITTER_TIME 6
84 SOFTDWN_TEST 1
TOTALS (# BYTES) 38 18 65 119
Table 3.16 View Object for Transducer Block SC202/ISC202
Realtive
Index
Parameters
Mnemonic
View
1
View
2
View
3
View
4
0 BLK_DATA
1 ST_REV 2 2 2 2
2 TAG_DESC[32]
3 STRATEGY 2
4 ALERT_KEY 1
5 MODE_BLK 4 4
6 BLOCK_ERR 2 2
7 UPDATE_EVT
8 BLOCK_ALM
9 TRANSDUCER_
DIRECTORY[2]
10 TRANSDUCER_TYPE 2 2 2 2
11 XD_ERROR 1 1
12 COLLECTION_
DIRECTORY[7]
13 PRIMARY_VALUE_
TYPE
2
14 PRIMARY_VALUE 5 5
15 PRIMARY_VALUE_
RANGE
11
16 SENSOR_CONST 4
17 CAL_POINT_HI 4
18 CAL_POINT_LO 4
19 CAL_MIN_SPAN 4
20 SENSOR_CAL_
METHOD
1
21 SENSOR_CAL_DATE 8
22 SECONDARY_VALUE 5 5
23 SECONDARY_VALUE_
UNIT
2
24 SENSOR_TEMP_COMP 1
25
SENSOR_TEMP_MAN_
VALUE
26 SENSOR_TYPE_TEMP 2
27
SENSOR_CONNECTION_
TEMP
1
28 SENSOR_TYPE_COND 2
29 SENSOR_OHMS
Table 3.15 View Object for Transducer Block PH202 Table 3.15 View Object for Transducer Block PH202
(contineous)