User Manual
13
IM 04L31A01-05E
PA Program pattern end signal
When the event output setting method is separate
Syntax PA p1,p2,p3<terminator>
p1: Pattern number (1 to 30)
p2: Enable/disable relay output (Off, On)
p3: Relay number*
*: DO001 to DO006
DO101 to DO106
DO201 to DO206
RO001 to RO012 (expansion module)
SW001 to SW036 (internal switch)
DO001 to DO006, SW001 to SW018 on the CX1000.
Query PA?
When the event output setting method is Common
Syntax PA p1,p2<terminator>
p1: Enable/disable relay output (Off, On)
p2: Relay number*
*: DO001 to DO006
DO101 to DO106
DO201 to DO206
RO001 to RO012 (expansion module)
SW001 to SW036 (internal switch)
DO001 to DO006, SW001 to SW018 on the CX1000.
Query PA?
Basic Setting Commands (Measurement)
XU Sets the channel identification display, memory alarm
time, language, whether or not to use the partial expanded
display function and the batch function
Syntax XU p1,p2,p3,p4<terminator>
p1: The display used to identify the measurement/computation channels (TAG,
CHANNEL)
p2: Memory alarm time (OFF, 1H, 2H, 5H, 10H, 20H, 50H, 100H)
p3: Language (ENGLISH, JAPANESE, GERMAN, FRENCH, CHINESE)
p4: Use/Not use partial expanded display function (USE, NOT)
Query XU?
Example Set the display used to identify the measurement/computation channels to channel
numbers, the memory alarm length to 1 hour, the language to English, use the partial
expansion function and the batch function.
XU CHANNEL,1H,ENGLISH,USE,USE
Description The SP command can be used when parameter p4 of this command is set to USE.
Communication Commands