Owner's manual

7-4 IM 04L31A01-01E
When set to [TC] (thermocouple input)
Range Selectable Measurement Span Range
R 0.0 to 1760.0 °C
S 0.0 to 1760.0 °C
B 0.0 to 1820.0 °C
K –200.0 to 1370.0 °C
E –200.0 to 800.0 °C
J –200.0 to 1100.0 °C
T –200.0 to 400.0 °C
N 0.0 to 1300.0 °C
W 0.0 to 2315.0 °C
L –200.0 to 900.0 °C
U –200.0 to 400.0 °C
PLATI 0.0 to 1400.0 °C
PR 0.0 to 1900.0 °C
WRe 0.0 to 2400.0 °C
When set to RTD (resistance temperature detector)
Range Selectable Measurement Span Range
Pt100 –200.0 to 600.0 °C
JPt100 –200.0 to 550.0 °C
When set to [DI] (ON/OFF input)
Range Selectable Measurement Span Values
Level 0: Less than 2.4 V,
1: Greater than or equal to 2.4 V
Cont 0: Open, 1: Closed
When set to [Delta] (difference computation)
Type Range Selectable Measurement Span Range
Voltage 20mV –20.00 to 20.00 mV
60mV –60.00 to 60.00 mV
200mV –200.0 to 200.0 mV
2V –2.000 to 2.000 V
6V –6.000 to 6.000 V
20V –20.00 to 20.00 V
50V –50.00 to 50.00 V
TC R –1760.0 to 1760.0 °C
S –1760.0 to 1760.0 °C
B –1820.0 to 1820.0 °C
K –1570.0 to 1570.0 °C
E –1000.0 to 1000.0 °C
J –1300.0 to 1300.0 °C
T –600.0 to 600.0 °C
N –1300.0 to 1300.0 °C
W –2315.0 to 2315.0 °C
L –1100.0 to 1100.0 °C
U –600.0 to 600.0 °C
PLATI –1400.0 to 1400.0 °C
PR –1900.0 to 1900.0 °C
WRe –2400.0 to 2400.0 °C
RTD Pt100 –800.0 to 800.0 °C
JPt100 –750.0 to 750.0 °C
DI Level –1 to 1
Cont –1 to 1
7.1 Settings Related to Measurement Inputs