Instruction Manual

7-30 IM 04L31A01-17E
Event Data
The MI command is used to output the FIFO data.
The ID number of the output format is “12.” See “Identifier” on page 7-3.
Header
Block 1
. . .
Block n
BINARY data
(The BINARY data section
on the “Conceptual diagram”
on page 7-2.)
Header
Same as the “Header” for the display data.
Block
2 bytes
4 bytes
Computed data
. . .
. . .
Measured data
. . .
. . .
Control data
. . .
. . .
Special Data Values
The measured/computed/control data take on the following values under special
conditions.
Special Data Value Type Measured/Control Data Computed Data
+ Over 7FFFH 7FFF7FFFH
– Over 8001H 80018001H
Skip 8002H 80028002H
Error 8004H 80048004H
Undefined 8005H 80058005H
Note
The measured/computed/control data is output according to the byte order specified with the BO
command.
Manual Sampled Data
The ME or MO command is used to output the data.
The ID number of the output format is “4.” See “Identifier” on page 7-3.
For a description of the data format, see the
user’s manual IM 04L31A01-01E
or
IM
04L31A01-03E
.
Report Data (Hourly, Daily, Weekly, and Monthly)
The ME or MO command is used to output the data.
The ID number of the output format is “5” for the hourly data, “6” for the daily data, “7”
for the weekly data, and “8” for the monthly data. See “Identifier” on page 7-3.
For a description of the data format, see the
user’s manual IM 04L31A01-01E
or
IM
04L31A01-03E
.
7.3 Output Format of BINARY Data