Instruction Manual
6-13
IM 04L31A01-17E
Command
6
6.3 Input Range Parameter
The following tables show which measurement ranges of the instrument correspond to
the input types of the CR command (control input range setting command) and SR
command (input range setting command), VOLT, TC, RTD, DI, and SQRT. The table
also shows the ranges for the upper and lower limits of the span.
DC Voltage (VOLT) and Square Root Computation (SQRT)
Measurement Range Parameter for the Upper and Lower Upper and Lower Limits
CR/SR Command Limits of the Span of the Span for the CR/SR
Command
20 mV 20mV –20.00 to 20.00 mV –2000 to 2000
60 mV 60mV –60.00 to 60.00 mV –6000 to 6000
200 mV 200mV –200.0 to 200.0 mV –2000 to 2000
2 V 2V –2.000 to 2.000 V –2000 to 2000
6 V 6V –6.000 to 6.000 V –6000 to 6000
20 V 20V –20.00 to 20.00 V –2000 to 2000
50 V 50V –50.00 to 50.00 V –5000 to 5000
Thermocouple (TC)
Measurement Range Parameter for the Upper and Lower Upper and Lower Limits
CR/SR Command Limits of the Span of the Span for the CR/SR
Command
RR0.0 to 1760.0 °C0 to 17600
SS0.0 to 1760.0 °C0 to 17600
BB0.0 to 1820.0 °C0 to 18200
KK–200.0 to 1370.0 °C –2000 to 13700
EE–200.0 to 800.0 °C –2000 to 8000
JJ–200.0 to 1100.0 °C –2000 to 11000
TT–200.0 to 400.0 °C –2000 to 4000
NN0.0 to 1300.0 °C0 to 13000
WW0.0 to 2315.0 °C0 to 23150
LL–200.0 to 900.0 °C –2000 to 9000
UU–200.0 to 400.0 °C –2000 to 4000
PLATI PLATI 0.0 to 1400.0 °C0 to 14000
PR PR 0.0 to 1900.0 °C0 to 19000
WRe WRe 0.0 to 2400.0 °C0 to 24000
Resistance Temperature Detector (RTD)
Measurement Range Parameter for the Upper and Lower Upper and Lower Limits
CR/SR Command Limits of the Span of the Span for the CR/SR
Command
Pt100 PT -200.0 to 600.0 °C –2000 to 6000
JPt100 JPT –200.0 to 550.0 °C –2000 to 5500
Cu10 (GE)
*
CU1 –200.0 to 300.0 °C –2000 to 3000
Cu10 (L&N)
*
CU2 –200.0 to 300.0 °C –2000 to 3000
Cu10 (WEED)
*
CU3 –200.0 to 300.0 °C –2000 to 3000
Cu10 (BAILEY)
*
CU4 –200.0 to 300.0 °C –2000 to 3000
Cu10 α=0.00392 CU5 –200.0 to 300.0 °C –2000 to 3000
at 20 °C
*
Cu10 α=0.00393 CU6 –200.0 to 300.0 °C –2000 to 3000
at 20 °C
*
Cu25 α=0.00425 at 0 °C
*
CU25 –200.0 to 300.0 °C –2000 to 3000
* Input range that can be specified on models with the Cu10, Cu25 resistance temperature detector
option /N1.