Instruction Manual
6-4 IM 04L31A01-17E
6.2 A List of Commands
Setting Commands (Control)
Command Command Function Execution mode ADMINISTRATOR USER Page
Type Name
Control Input Range
CR Sets the control range Operation mode Yes No 6-15
MP Control range settings Operation mode Yes No 6-16
(used during control computations)
MB Bias Operation mode Yes No 6-16
MF Filter Operation mode Yes No 6-17
RS Set the ratio Operation mode Yes No 6-17
Control Alarm
AT Sets the control alarm Operation mode Yes No 6-17
AV Sets the control alarm value Operation mode Yes No 6-17
Operation-related Parameters
HS Sets the suppressing function Operation mode Yes No 6-17
HT Sets the ramp-rate-time unit Operation mode Yes No 6-17
HH Sets the SP ramp-up-rate Operation mode Yes No 6-18
HL Sets the SP ramp-down-rate Operation mode Yes No 6-18
HM Sets the loop tag and tag comment Operation mode Yes No 6-18
GC Zone PID setting 1 (reference points) Operation mode Yes No 6-18
GD Zone PID setting 2 (switching hysteresis) Operation mode Yes No 6-18
HW Zone PID setting 3 (reference deviation) Operation mode Yes No 6-18
PID Parameters
GO Sets the target setpoint Operation mode Yes No 6-18
HP Sets the proportional band Operation mode Yes No 6-18
HI Sets the integral time Operation mode Yes No 6-18
HD Sets the derivative time Operation mode Yes No 6-19
HO Sets control-related parameters Operation mode Yes No 6-19
Control Group Settings
FG Sets the control group name Operation mode Yes No 6-19
GG Sets the control group Operation mode Yes No 6-19
Ten-segment lIinearizer Input/Output
HA Sets the ten-segment linearizer mode Operation mode Yes No 6-20
HE Sets the ten-segment linearizer segment Operation mode Yes No 6-20
Pattern Initial Setting
PB Sets initial patterns Operation mode Yes No 6-20
PI Operating loop settings Operation mode Yes No 6-20
Wait Action Setting
PZ Sets the wait zone Operation mode Yes No 6-21
PW Sets the wait time Operation mode Yes No 6-21
Program Initial Setting
PO Sets the start setpoint Operation mode Yes No 6-21
PQ Sets the start code Operation mode Yes No 6-21
Program Operation Parameters
PD Sets the ramp/soak select Operation mode Yes No 6-21
PM Sets the final target setpoint Operation mode Yes No 6-21
PT Sets the segment time Operation mode Yes No 6-21
PU Sets the ramp-rate time unit/ramp Operation mode Yes No 6-21
PG Segment PID group number Operation mode Yes No 6-21
PJ Sets the segment shifting action and wait Operation mode Yes No 6-21
Yes: Command usable
No: Command not usable