Instruction Manual
4-36
IM WX102-01E
Chart Speed Settings
Chart Speed 1 (CHART)
This setting specifies the chart speed of ordinary trend recordings. The setting ranges 
from 1 to 1500mm/h, in 1 mm steps. The default setting is 100mm/h.
Chart Speed 2 (CHART2)
This setting consists of a chart speed and recording interval. Depending on the Event/
Action function, the chart speed and recording interval will change into chart speed 2 and 
its corresponding interval.
•
  Chart speed 2 setting
  This setting is the same as for chart speed 1, and its default setting is 100mm/h.
•  Recording interval
  This setting species the recording interval for the digital printout in the logging and 
analog trend recording mode. Set either the Absolute or Relative interval
If the SPEED CHG action is selected as event/action setting, the Recording Interval will 
be change as follows:
T
rend Recording
•
  Normal: Speed set as Chart Speed 1
•  When an event occurs: Speed set as Chart Speed 2
Logging Recording
•  Normal: Depends on the (SETUP) Recording Format settings for the Recording 
interval in digital printing/logging. It can be set to Single or Multiple:
  Single- Interval for timer one.
  Multiple- Intervals selected from 6 kinds of timers.
•  When an event occurs: Interval set as Chart Speed 2.
Entering a Header
HEADER LINE No.: One header can consist of up to five lines. 
LINE 1 to 5: The header contents can be entered here using up to 80 alphanumerics for 
each line, and thus up to 400 characters for the entire header. The default setting is all 
spaces. To print the header press the Print button on the DR and select HEADER START 
from the menu.
Entering a Title
One title can be set, using up to 32 alphanumerics. Set the Title printing pitch to 600 mm, 
1500 mm or set it OFF, in the (SETUP) Recording Format setting screen.
Setting the List Format
The List Format (LIST FMT) setting specifies which setting information will be printed out 
in case of list printouts. Each of the following lists can be selected ON or OFF, and the 
default setting is ON.
Print setting range info: Information about settings related to tags, type of input, recording 
span, linear scaling and computation equation.
Print alarm settings info
Print printing settings info (LIST PRINT) : Information about settings related to analog trend 
recording, digital printout, interpolation, recording zones, partial expanded recording, recording 
interval of digital printouts for logging mode and analog mode, moving average, scaled values, 
alarm printout, manual printout and data saving ON/OFF.
Print other settings info: Information about settings related to match time, groups, headers, 
messages, event/action function, list format and computation constant.
Information which always be included in a list printout, regardless of the above settings, are title, 
measurement interval, recording interval (trend), chart speeds 1 and 2, recording mode and time.
4.16 Printing Settings (DR Only)










