Instruction Manual
1-18
IM WX102-01E
•  Math computation start/stop/clear/reset
Clear:
  When issued during the computation, the measured data is reset before doing the 
rst computation.
Computation clear
Computed data
Computation start
Measurement interval
Reset:
  When issued during the computation, the measured data is reset after doing the 
rst computation.
Measurement interval
Computation start Computation
reset
Computed data
•  Report start/stop
  For models with Report option it is possible to start/stop reporting.
Computation (Uniquely for DA100 with /M1 option)
The DA100 can execute computations with the measured data of each input channel 
taken as a variable. The results can be displayed or saved. The following operators can 
be used for computation.
Basic operators
Type Operator Example Description
Addition + 001+002 To obtain the sum of the measured data of channel 001 
and channel 002.
Subtraction - 002-001 To obtain the difference of the measured data of 
channel 002 and channel 001.
Multiplication * 003*K1 To multiply constant K1 to the measured data of channel 
003.
Division  / 004/K2 To divide the measured data of channel 004 by constant 
K2.
Power ** 005**006 To take the power of measured data of channel 005 with 
the measured data of channel 006.
Absolute 
value
ABS() ABS(001)  To obtain the absolute value of the measured data of 
channel 001.
Square root SQR() SQR(002) To obtain the square root of the measured data of 
channel 002.
Common 
logarithm
LOG() LOG(003) To obtain the common logarithm of the measured data 
of channel 003.
Natural 
Logarithm
LN() LN(004)  To obtain the natural logarithm of the measured data of 
channel 004.
Exponent EXP() EXP(005) To make the measured data of channel 005 to be x and 
obtain e
x
.
* +/- can be used as signs as in -(001).
1.5 DA100 Functions