User guide
2-8
IM WX101-01E
2.5 Setting the Security
To prevent mis operation, you can set an operation level to each project.
In addition to this operation level, DAQLOGGER’s security function offers password
protection and desktop protection.
Setting Operation Level to a Project
For individual projects, you can set an operation level selecting from “Supervisor,”
“Operator,” and “User.”
Under these operation levels, operation will be limited as follows.
Function Supervisor Operator User
Logging Software No limitation No limitation Setting change disabled
Start/Stop operation possible
Data Monitor No limitation No limitation No limitation
Historical Viewer No limitation No limitation No limitation
DDE Server No limitation No limitation Setting change disabled
Pause/Resume operation possible
Monitor Server No limitation No limitation Setting change disabled
Pause/Resume operation possible
Report Generator No limitation No limitation Setting change disabled
Start/Stop operation possible
Group Editor No limitation No limitation Saving disabled
Hardware Configurator No limitation Sending and
saving disabled
Sending and
saving disabled
Tag Editor No limitation Saving disabled Saving disabled
Software Configurator No limitation Operation disabled Operation disabled
File Utility No limitation No limitation No limitation
Event Processor No limitation No limitation Setting change disabled Start/Stop
operation possible
Control Server No limitation No limitation Setting change disabled Start/Stop
Procedure
The operation level is only set for the process of creating a new project and cannot be
changed once it is set.
Setting the operation level is not an independent operation but is carried out in step 4 of
“Creating a New Project” in section 2.4.
4.
In the “Level” list box, select the operation level you wish to set.