User guide

7-103
IM WX101-01E
1
2
3
4
5
6
7
8
9
Index
Setting the Recorder
Send delay [second]
Set the delay between POP3 server authentication and transmission to a value from 0
to 10 seconds.
POP3 Login
To encrypt the password when logging into the POP3 server, select APOP. To send it
in plain text, select PLAIN.
Auth. Settings (Release number 4 or later)
To enable support for authenticated e-mail transmission (Authentication SMTP), set a
user name and password to use for authentication.
User name
Enter the user name. You can enter up to 32 characters.
Password
Enter the password. You can enter up to 32 characters. The password is displayed
as “**********.”
Alarm
Specify the settings for sending e-mail when alarms occur.
Recipient1 and Recipient2
Set the e-mail recipients. For Recipient1 and Recipient2, select [ON] to send e-mail
or [OFF] to not send e-mail.
Active alarms
Sends an e-mail when an alarm occurs. You can select [ON] (send e-mail) or [OFF] (not
send e-mail) for alarms 1 to 4.
Include INST
Select [ON] to attach instantaneous value data to e-mail. The data that is attached
to an e-mail is the instantaneous value that is measured at the time the e-mail is
transmitted.
Include source URL
Select [ON] to attach the source URL. Attach the URL when the Web server is enabled.
Subject
Enter the subject of the e-mail using up to 32 alphanumeric characters. The default
setting is Alarm_summary.
Header1, Header2
Enter header 1 and header 2 using up to 64 characters.
Send alarm action (Release number 3 or later)
To send an e-mail when an alarm occurs and when it is cleared, select [ON+OFF]. To
only send an e-mail when an alarm occurs, select [ON].
Include tag/ch in Subject (Release number 3 or later)
Select [ON] to include a tag number in the subject. If the tag number is not set, the
corresponding channel number is included.