User guide
1-14
IM WX13-01E
1.1 Overview of Functions
• Saving the Data to a Single File or Multiple Files
The data in the logging period can be divided and saved in the following fashion.
Data count: When a specied number of data points (logging count) is written to a
le, AddTrigger starts writing data to a new data le.
The number of data
points of the last data le to which data is written may be less than the
specied number of data points.
per Day:
AddTrigger starts writing data to a new data le at 0 hour 0 min 0s every
day.
per Hour:
AddTrigger starts writing data to a new data le at 0 min 0s every hour.
Saving to a single file
XX:00:00 XX:00:00
00:00:0000:00:00
Save to a single file
Data count division
per Hour division
per Day division
Logging period
Logging period Logging period
Logging period
Logging period
Logging period
Logging period
Logging period
Number of data points for dividing the file
Time
Time
Time