Instruction Manual

2-14
IM WX1-04E
2.4 Viewing the Status of the Executable Function
Displaying the Connection Status
Procedure
1.
Choose View > State Display.
The GateOPC Information Software dialog box opens, allowing you to see the
method under which the executable function may be running (as a process or as
a service), whether or not it is running, and with which PCs communications are
open.
Displays the names
of connected clients
Double-click to display
the Error Indicator dialog box
Displays the communications status with the client
Gray: Stopped
Red: Error
Green: Normal
See section 3.3 for error messages.
Note
If a warning message is displayed (code Wxxxx), the lamp that displays the connection
status by color does not blink red.
When an error occurs and the lamp blinks red, the Error Indicator dialog box appears. If you
close the dialog box, the lamp turns green.