Owner manual

App-10
IM MV1000-01E
Manually Sampled Data
The MV generates manually sampled data to a tab-separated text file that contains
numeric values and text.
The MV does not generate values for measurement channels set to Skip or for
computation or external input channels set to Of
f.
Data is added to the file each time you carry out a manual sampling operation.
Format
YRECCRLF
Manual Sample Data Version 1.00.00CRLF
Model MV2000CRLF
Language Code shift-JISCRLF
File Status ffffffffCRLF
Serial No. III•••ICRLF
File Header HHH•••HCRLF
Ch ccccc
ccccc
••• cccccCRLF
Tag ttt•••t ttt•••t
••• ttt•••tCRLF
Unit uuuuuu uuuuuu
••• uuuuuuCRLF
yyyy/mo/dd hh:mi:ss nnn•••n nnn•••n
••• nnn•••nCRLF
ffffffff
File status (eight characters)
Complete
Completed
Progress
Data being added
Decrease
Defective
III•••I
MV serial number (16 characters)
HHH•••H
File header (50 characters)
ccccc
Channel number (five characters)
ttt•••t
Tag name (16 characters)
uuuuuu
Unit (six characters)
yyyy/mo/dd hh:mi:ss
Year, month, day, and time of sampling (19 characters)
nnn•••n
Measured value (13 characters)
Appendix 3 Text File Formats