Manual
5-13
IM MV1000-17E
Responses
1
2
3
4
5
6
7
App
Index
xxxxxxxxxx
Returns a login history left-justified.
Login:
Login
Logout:
Logout
NewTime:
New time
TimeChg:
Time change
PowerOff:
Power Off
PowerOn:
Power On
TRevStart:
Start of gradual time adjustment
TRevEnd:
End of gradual time adjustment
TimeDST:
Switching of the daylight savings time
SNTPtimset:
Time change by SNTP
nnn
Operation property
KEY:
Key operation
COM:
Communication
REM:
Remote
ACT:
Event action
SYS:
System
uuu···u
User name (up to 20 characters)
_
Space
• Example
EA
99/05/11 12:20:00 Login KEY administrator
99/05/11 12:30:00 Logout KEY administrator
99/05/11 12:20:00 Login COM user
99/05/11 12:30:00 Logout COM user
EN
Web Operation Log
• The MV returns the log of operations on the Web screen in response to an FL
command.
• The MV retains a maximum of 50 operations. Logs that exceed 50 are cleared from
the oldest ones.
•
Syntax
EACRLF
yy/mo/dd_hh:mm:ss_ffffff_eee_???···?CRLF
···································
ENCRLF
yy
Year (
00
to
99
)
mo
Month (
01
to
12
)
dd
Day (
01
to
31
)
hh
Hour (
00
to
23
)
mm
Minute (
00
to
59
)
ss
Second (
00
to
59
)
ffffff
Requested operation
SCREEN:
Screen change
KEY:
Key operation
MSG:
Message assignment/write
CREATE:
File generation
5.2 Text Data Output Format