User Manual

IM 01E20F02-01E
6-3
6. IN-PROCESS OPERATION
Table 6.1 Status of each parameter in failure mode (2/2)
40:PB O/S ModeO/S
Mode
Alarms
41:TB O/S Mode
42:AI FB O/S Mode
43:Total1 FB O/S
Mode
44:Total2 FB O/S
Mode
45:Total3 FB O/S
Mode
46:DI1 FB O/S
Mode
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
Uncertain;
Substitude Value,
ok
Uncertain Non
Specific, ok
Bad;
Out of Service,
Const.
Uncertain;
Last Usable Value,
Const.
Bad;
Out of Service,
Const.
Uncertain Non
Specific, ok
Uncertain Non
Specific, ok
Uncertain;
Last Usable Value,
Const.
Uncertain Non
Specific, ok
Uncertain Non
Specific, ok
Uncertain;
Last Usable Value,
Const.
Uncertain Non
Specific, ok
Bad;
Out of Service,
ok
Uncertain;
Last Usage Value,
ok
Uncertain;
Substitude Value,
ok
Uncertain;
Last Usage Value,
ok
Bad;
Out of Service,
ok
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
Bad;
Out of Service,
Const.
––
TOT1: Bad;
Out of Service,
Const.
TOT2: –
TOT3: –
TOT1: Bad;
Out of Service,
Const.
TOT2: –
TOT3: –
TOT1: Bad;
Out of Service,
Const.
TOT2: –
TOT3: –
––
TOT1: –
TOT2: Bad;
Out of Service,
Const.
TOT3: –
––
TOT1: –
TOT2: –
TOT3: Bad;
Out of Service,
Const.
TOT1: –
TOT2: Bad;
Out of Service,
Const.
TOT3: –
TOT1: –
TOT2: –
TOT3: Bad;
Out of Service,
Const.
TOT1: –
TOT2: Bad;
Out of Service,
Const.
TOT3: –
TOT1: –
TOT2: –
TOT3: Bad;
Out of Service,
Const.
––
DI1: Bad; Out of
Service,
Const.
DI2: –
DI1: Bad; Out of
Service,
Const.
DI2: –
47:DI2 FB O/S
Mode
DI1: –
DI2: Bad; Out of
Service,
Const.
DI1: –
DI2: Bad; Out of
Service,
Const.
50:Span > 10m/s
Setting
Alarms
Uncertain;
Substitude Value,
ok
Bad;
Non specific,
Const.
Uncertain;
Last Usage Value,
ok
Uncertain;
Substitude Value,
ok
Bad;
Non specific,
Const.
Uncertain;
Last Usage Value,
ok
Uncertain;
Substitude Value,
ok
Uncertain;
Last Usage Value,
ok
51:Span < 0.1m/s
57:Dens Set Err
56:H/L HH/LL Set
71:Meas Mod Set
72:Size Set Err
73:Adh Set Err
120:Total1 Unit
Set Err
TOT1:Bad;
Configuration
Error, ok
TOT2: –
TOT3: –
121:Total2 Unit
Set Err
TOT1: –
TOT2:Bad;
Configuration
Error, ok
TOT3: –
122:Total3 Unit
Set Err
TOT1: –
TOT2: –
TOT3:Bad;
Configuration
Error, ok
TOT1:Bad;
Configuration
Error, ok
TOT2: –
TOT3: –
TOT1: –
TOT2:Bad;
Configuration
Error, ok
TOT3: –
TOT1: –
TOT2: –
TOT3:Bad;
Configuration
Error, ok
TOT1:Bad;
Configuration
Error, ok
TOT2: –
TOT3: –
TOT1: –
TOT2:Bad;
Configuration
Error, ok
TOT3: –
TOT1: –
TOT2: –
TOT3:Bad;
Configuration
Error, ok
DI1: Bad; Out of
Service,
Const.
DI2: –
DI1: –
DI2: Bad; Out of
Service,
Const.
Bad;
Non specific,
Const.
Uncertain;
Substitude Value,
ok
Uncertain;
Last Usage Value,
ok
Bad;
Non specific,
Const.
Category Alarm
FSAFE_TYPE = 0
AI Block
FSAFE_TYPE = 1 FSAFE_TYPE = 2 FAIL_TOT = 0 FAIL_TOT = 1 FAIL_TOT = 2
TOT Block
FSAFE_TYPE = 0
DI Block
FSAFE_TYPE = 1 FSAFE_TYPE = 2