10.1 Compressed Air Line Sizes
Compressed air lines should be sized to hold pressure drops to a minimum. So not used restrictive ttings such as quick
connects. They can “starve” the Vortex Tube by causing line pressure drop. The following chart gives suggested line sizes
for pipe and hose.
Line Sizes for Runs Up To:
10 FT
(3 M)
10 - 50 FT
(3 - 15 M)
50 - 100 FT
(15 - 30.5M)
Pipe Hose Pipe Hose Pipe Hose
1/4” 3/8” 3/8” 1/2” 1/2” 5/8”
10.1.1 Compressed Air Supply
For best performance, use line pressure 80 to 100 PSIG (5.5 – 6.9 BAR). Vortex Tubes are rated in SCFM (SLPM) at 100
PSIG (6.9 BAR) supply pressure.
With proper ltration and separation for dirt, moisture and oil from the compressed air supply, the Vortex Tube will run for
years with no maintenance required. Use a 25 micron or smaller lter separator that is sized to SCFM (SLPM) rating of the
Vortex Tube.
To prevent problems associated with oil, use an appropriate Oil Removal Filter for Vortex Tubes up to 30 SCFM (850
SLPM) . The oil removal lter should be used downstream from the automatic drain lter separator. Filter should be used
within 10 to 15 ft ( 3 to 4.6 m ) of each Vortex Tube.
For Replacement or Repair lter and regulator parts contact Yokogawa.
10.1.2 Setting the Vortex Tube
Hot and cold temperatures produced by a Vortex Tube are innitely variable by adjusting the slotted valve at the hot air
exhaust. Opening the valve reduces the cold airow and the cold air temperature, Closing the valve increases the cold
airow and the cold air temperature.
Set the Vortex Tube with a thermometer. To measure temperature accurately, it should be inserted into the cold muer or
a piece of tubing on the cold end exhaust.
10.1.3 Troubleshooting & Maintenance
If the Vortex Tubes Does Not perform properly, check for these common problems:
1.) Loosed Cold Cap or Cold Muer- A loosed cold cap or cold muer will cause poor performance. Make sure it is tight.
2.) Inlet Pressure- Low inlet pressure supply will cause poor performance. Measure the pressure at the compress air