Owner manual
2. SPECIFICATION
General
Energy Display units: kWh, MWh, MJ, GJ, therm, BTU x 1000,
tons x hours (refrigeration).
Maximum Thermal
Power: 3000 MW.
Accuracy Class: OIML R75 Class 4,
EN1434.
Measurement Time: 0.5 sec time interval.
Environmental Class: EN1434 Classes A & C.
Ambient Temp Range: 0°C to 60°C.
Storage Temp Range: -20°C to 70°C.
Temperature Measurement
Type of Sensor: Pt100 to IEC751.
Temperature Range: -10°C to 220°C
Temperature Difference: 1K to 200K.
Approved Temp Range: 1°C to 200°C.
Approved Temp Difference: 3K to 199K.
Measurement Time: 3 sec time interval.
Display
Type: LCD with 7 digit numeric display and 11
character display.
Digits: 15.5mm (0.6") high.
Characters: 6mm (0.24") high.
Specification 7