User's Manual
User’s
Manual
P.1/4IM 01W06E01-01EN
YOKOGAWA ELECTRIC CORPORATION
Headquarters
9-32, Nakacho, 2-chome, Musashino-shi, Tokyo, 180-8750 JAPAN
Phone : 81-422-52-5555
Branch Sales Offices
Osaka, Nagoya, Hiroshima, Kurashiki, Fukuoka, Kitakyusyu
YOKOGAWA EUROPE B. V.
Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS
Phone : 31-88-4641000 Fax : 31-88-4641111
YOKOGAWA ENGINEERING ASIA PTE. LTD.
5 Bedok South Road, Singapore 469270, SINGAPORE
Phone : 65-6241-9933 Fax : 65-6241-2606
YOKOGAWA CORPORATION OF AMERICA
Head Office
12530 West Airport Blvd, Sugar Land, Texas 77478, USA
Phone : 1-281-340-3800 Fax : 1-281-340-38382606
Nov. '19
Printed in Japan
3rd Edition: Nov. 2019 (KP)
All Rights Reserved, Copyright © 2018, Yokogawa Electric Corporation
IM 01W06E01-01EN
3rd Edition
XS770A
Wireless Vibration Sensor
Startup Guide
IM 01W06E01-01EN
1. Introduction
Thank you for purchasing the XS770A Wireless Vibration Sensor.
Your XS770A was precisely calibrated at the factory before shipment. To ensure both
safety and efciency, please read this manual and the following related documents
carefully before you operate the instrument.
Document Name Document No.
General Specication
XS770A Wireless Vibration Sensor
GS 01W06E01-01EN
User's Manual
XS770A Wireless Vibration Sensor Startup Guide
IM 01W06E01-01EN
(This document)
User's Manual
XS770A Wireless Vibration Sensor Functions
IM 01W06E01-11EN
This manual describes important information to enable appropriate and safe use,
installation and maintenance of the XS770A. The XS770A functional explanation,
settings, operation, and maintenance are described in the User's Manual “IM 01W06E01-
11EN”. Before beginning to operate this device, always read these documents to learn
how to use this product correctly. The User's Manual (PDF le) can be downloaded from
the website (http://www.sushisensor.com/).
Regarding This Manual
• This manual should be provided to the end user.
• This manual and the identication tag attached on the packing box are essential parts
of the product; keep them in a safe place for future reference.
• The contents of this manual are subject to change without prior notice.
• All rights reserved. No part of this manual may be reproduced in any form without
Yokogawa’s written permission.
• Yokogawa makes no warranty of any kind with regard to this manual, including, but
not limited to, implied warranty of merchantability and tness for a particular purpose.
• If any question arises or errors are found, or if any information is missing from this
manual, please inform the nearest Yokogawa sales ofce.
• The specications covered by this manual are limited to those for the standard type
under the specied model number break-down and do not cover custom-made
instruments. When products whose sufx code or optional codes contain code “Z”
and an exclusive document is attached, please read it along with this manual.
• Please note that changes in the specications, construction, or component parts of
the instrument may not immediately be reected in this manual at the time of change,
provided that postponement of revisions will not cause difculty to the user from a
functional or performance standpoint.
Safety, Protection, and Modication of this Product
• This product is designed to be used by a person with specialized knowledge.
• To protect the operator, product, and system controlled by the product, observe
the safety precautions described in this manual. If users handle contrary to these
instructions, we cannot guarantee safety.
• The Modication of the product is strictly prohibited.
• The following safety symbols are used in this manual:
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death
or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor
or moderate injury or physical damage. It may also be used to alert against unsafe
practices.
IMPORTANT
Indicates that operating the hardware or software in this manner may damage it or
lead to system failure.
NOTE
Draws attention to information essential for understanding the operation and features.
1.1 Safe Use of This Product
• Users of explosion protected instruments should refer rst to “8. Explosion Protected
Instrument”.
• The use of this instrument is restricted to those who have received appropriate
training for the device.
• Take care not to create sparks when accessing the instrument or peripheral devices
in a hazardous location.
• Repair or modication to this instrument by customer will cause a malfunction
of explosion protect function and hazardous situation. If you need to repair or
modication, please contact the nearest Yokogawa ofce.
1.2 Radio Waves
This product is designated as a certication of construction type as a wireless facility for
800 MHz band and 900 MHz band low-power data communication system of the Radio
Act. Refer to “7.2 Regulatory Compliance Statements” for detail.
• Area Code 2: Regional parameter is EU868 and frequency is 863 to 870MHz.
Sweden and Greece do not allow full use of the 863 to 870 MHz band.
Detail of the restrictions, refer to EC Decision 2006/771/EC (as amended).
• Area Code3: Regional parameter is US915 and frequency is 902 to 928MHz.
Available frequency bands vary depending on the country.
•
Area Code 4:
Regional parameter is AS923 and frequency is 919 to 925 MHz .
Available frequency bands vary depending on the country.
IMPORTANT
• Due to the designated certication of construction type, users may be subject to
legal punishment in case of disassembling or modifying this product.
• Preventing interference with other wireless stations
Industrial, scientic, and medical equipment, as well as local wireless stations
(license required) and specic low power wireless stations (license not required)
for identifying mobile objects used in factory production lines, use the same
frequency band as this product.
• Check that local wireless stations and specic low-power wireless stations are not
being used in the vicinity before using this product.
• If this product causes radio interference in a local wireless station, stop the
emission of radio waves immediately. For details on how to prevent radio
interference, contact our service ofce.
1.3 Warranty
• The warranty shall cover the period noted on the quotation presented to the
purchaser at the time of purchase. Problems occurring during the warranty period
shall basically be repaired free of charge.
• If any problems are experienced with this product, the customer should contact the
Yokogawa representative from which this product was purchased or the nearest
Yokogawa ofce.
• If a problem arises with this product, please inform us of the nature of the problem
and the circumstances under which it developed, including the model specication
and serial number. Any diagrams, data and other information you can include in your
communication will also be helpful.
• The party responsible for the cost of xing the problem shall be determined by
Yokogawa following an investigation conducted by Yokogawa.
The purchaser shall bear the responsibility for repair costs, even during
the warranty period, if the malfunction is due to:
• Improper and/or inadequate maintenance by the purchaser.
• Malfunction or damage due to a failure to handle, use, or store this product in
accordance with the design specications.
• Use of this product in question in a location not conforming to the standards specied
by Yokogawa, or due to improper maintenance of the installation location.
• Failure or damage due to modication or repair by any party except Yokogawa or an
approved representative of Yokogawa.
• Malfunction or damage from improper relocation of this product in question after
delivery.
• Reason for force majeure such as res, earthquakes, storms/oods, thunder/
lightning, or other natural disasters, or disturbances, riots, warfare, or radioactive
contamination.
1.4 Trademarks
In this document, trademarks or registered trademarks are not marked with “™” or “®”.
Product names and company names in this document are trademarks or registered
trademarks of the respective companies.
2. Notes on Handling
The XS770A is fully factory-tested before shipment. When the XS770A is delivered,
check the appearance for damage and that all the components mentioned below are
included.
This section describes the precautions required to handle this product. Before use, read
this section thoroughly. For information about other items, refer to the relevant sections.
Bundled Items
• XS770A main unit (with built-in battery)
• Hexagon socket set screw
• Conversion Screw (Area Code 3 only)
• User's Manual (IM 01W06E01-01EN)
• Default key label
2.1 Check the Model and Specications
The model name and specications are written on the
nameplate attached to the housing. Verify that the specication
indicated in the “Model and Sufx Code” in General
Specications “GS 01W06E01-01EN” complies with the
specications written on the order sheet.
2.2 Transport
To prevent damage while in transit ,leave the XS770A in the
original shipping container until it reaches the installation site.
2.3 Storage
When an extended storage period is expected, observe the following precautions.
(1) Choose a storage location that satises the following requirements.
• A location that is not exposed to rain or water.
• A location subject to a minimum of vibration or impact.
• The following temperature and humidity range are recommended.
- Temperature: -20 to 40°C (-20 to 85°C with the battery removed)
- Humidity: 0 to 100% RH (non-condensation)
(2) If at all possible, store the transmitter in factory-shipped condition, that is, in the
original shipping container.
NOTE
When storing this product over a long period, it is recommended to put the instrument
in OFF Mode to conserve the battery. This product is shipped in OFF Mode from the
factory. For details on how to switch to OFF Mode, refer to “IM 01W06E01-11EN”.
2.4 Selecting the Installation Location
This product is designed to withstand severe environmental conditions. However, to
ensure that it will provide years of stable and accurate performance, take the following
precautions when selecting the installation location.
Wireless Communication
Ensure that there are no obstacles such as walls or pipes within a 30-cm radius of
each antenna.
Ambient Temperature
Avoid locations subject to wide temperature variations or a signicant temperature
gradient. If the location is exposed to radiant heat from plant equipment, provide
adequate thermal insulation and/or ventilation.
Ambient Atmosphere
Do not install the product in a location with a corrosive atmosphere. If this cannot be
avoided, ensure there is adequate ventilation.
2.5 Restrictions on Use of Radio Transceivers
IMPORTANT
Although this product has been designed to resist high frequency electrical noise, if a
radio transceiver is used near this product or its external wiring, this product may be
affected by high frequency noise pickup. To test this, start from a distance of several
meters and slowly approach this product with the transceiver while observing the
measurement loop for noise effects. Thereafter use the transceiver outside the range
where the noise effects were rst observed.
F01.ai
Figure2.1 Example of
Nameplate