System information

494 Logical Partitions on System i5
HMC CLI command attributes
Table A-7 lists the command attributes that are available, along with the commands in which
they are valid, and provides a description of each command.
Table A-7 HMC CLI command attributes
Command attributes
Attribute Used in command Description
activated_profile lssyscfg User defined name of the profile that was used when the
partition was activated.
addl_vlan_ids chhwres and lshwres List of additional VLAN IDs assigned to the virtual ethernet
adapter. Valid values are 2 - 4094, and the number of
additional VLAN IDs is limited by the maximum number of
VLAN IDs allowed per port (max_vlans_per_port). This
attribute is only valid for IEEE-compliant virtual ethernet
adapters.
alt_console_slot chhwres, chsyscfg, lshwres
lssyscfg, and mksyscfg
Complete physical location code of the slot that has the
alternate console device. A value of none indicates that
there is no alternate console device.
This attribute is
only valid for OS/400 partitions.
alt_load_source_slot chhwres chsyscfg lshwres
lssyscfg mksyscfg
Complete physical location code of the slot that has the
alternate load source I/O device. A value of none
indicates that there is no alternate load source I/O device.
This attribute is only valid for OS/400 partitions.
auto_ipl chsyscfg lssyscfg mksyscfg Indicates whether or not the partition should be activated
automatically when the managed system is powered on.
Valid values are 0 (no) and 1 (yes).
Attribute Used in command Description
backplane_phys_loc lshwres Physical location code of the backplane on which the bus
resides.
boot_mode chsyscfg lssyscfg mksyscfg The boot mode for the partition.
This attribute is only
valid for AIX/Linux partitions.
Valid values are norm
(normal), dd (diagnostic default boot path), sms (boot to
SMS menus), of (boot to Open Firmware prompt), and ds
(diagnostic stored boot path).
bus_class lshwres Possible values are RIO or integrated.
bus_grouping lshwres
bus_id lshwres
bus_num chhwres lshwres RIO bus (loop) number to be represented by the SMC
virtual I/O adapter
client_id lshwres Virtual serial and SCSI attribute.
client_type lshwres Virtual serial and SCSI attribute.
cluster_id chsyscfg, lssyscfg, and
mksyscfg
ID of the workload management (eWLM) cluster to which
the partition is assigned. A valid cluster ID is a number
between 0 and 32767, inclusive, or the value none, which
indicates that the partition is not assigned to any eWLM
cluster.