458 Logical Partitions on System i5
The next screen shown is the iSeries Recommended Fixes - Server Firmware: Update Policy
Set to Operating System Web page (Figure 14-47)
Figure 14-47 i5 recommended fixes Web site MHxxxxx- in-band
There are numerous ways of obtaining the i5 firmware. Normally the firmware is ordered by
using a marker PTF MHxxxxx. This marker PTF may have several co-requisite PTFs which
make up the firmware package.
򐂰 Order a firmware MHxxxxx 1 marker PTF electronically or on CD by using the
SNDPTFORD i5/OS command or Fix Central. For example, the SF225_096 firmware can
be ordered by using requesting PTF MH00248.
򐂰 Order the firmware by clicking the Go link 2 and ordering through the Internet. You must
have a registered IBM ID to order the HMC fixes through the Internet.
򐂰 MHxxxxx PTFs are also contained in both Cumulative PTF packages and the HIPER
Group package. You should check which firmware PTFs are included in these packages
before installing.
Installing i5 in-band firmware updates
In this section we show how to update the i5 firmware through an i5/OS service partition using
the MHxxxxx marker PTFs. After you have received the MHxxxxx PTFs they should be
loaded and applied using the standard i5/OS PTF procedure. Our example shows how to
update the managed system firmware from SF220_075 to SF225_096 using the marker PTF
MH00248. The system used in this exercise is running on the b-side for i5/OS and the t-side
for the server firmware - recommend normal system operations. Our example is based on
firmware levels available at the time of writing this redbook and may change with future
releases.
Important: You must have your firmware update policy set to operating system AND have
one of your i5/OS partitions set to be the service partition to be able to update the
managed systems firmware through the in-band method.