System information
Chapter 10. Using the Advanced Systems Management Interface 335
To perform concurrent maintenance, you would identify, by location code, the failing IDE
device you want to repair. You would then change the state of the “pair” of devices as shown
in Figure 10-90 by selecting a state of Off and clicking the Save settings button.
Figure 10-90 Example: IDE device power off using concurrent maintenance
You will next see a confirmation panel as shown in Figure 10-91. It is now safe to have the
service representative do a physical removal, or removal and replacement of the failing IDE
device.
Figure 10-91 Confirm IDE device power off
With the IDE device now replaced, you can now return and use the action shown previously
in Figure 10-89 on page 334 to power
On the pair containing the new IDE device, completing
the concurrent maintenance procedure.
Attention: If you power Off a pair of IDE devices, you should return later to power On the
IDE devices after the failing hardware has been replaced.