YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! INSTALLATION INSTRUCTION AND OPERATION MANUAL DC INVERTER R410A - SERIES 56 MINI SPLIT WALL MOUNT - SOLAR BOOSTED (PV TYPE) YMGI Group POB 1559 O'Fallon, MO 63366, USA Tel: (866)833-3138 Fax: (866)377-3355 Web Site: www.ymgigroup.com Email: info@ymgigroup.com Literature Part No: LIT-WMMS-(56)-DC IVTR-USER MANUAL-20131130 Subject to Continuous Engineering Change and Product Improvement without Notice.
CONTENTS WELCOME AND PLEASE READ THROUGH MANUALS 2 Dear Customer(s)/End User(s)/Unit Purchaser(s)/Installer(s)/Contractor(s): INSTALLING TECHNICIAN/CONTRACTOR'S JOBS AND RESPONSIBILITIES Thanks for choosing YMGI products.
WELCOME AND PLEASE READ THROUGH MANUALS INSTALLING TECHNICIAN/CONTRACTOR'S JOBS AND RESPONSIBILITIES YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! 1. Be sure to hire only one certified, licensed HVAC Company to complete 100% of the installation so that all details of the installation are clear, complete and well taken care of. 2.
LIMITED PRODUCT WARRANTY POLICIES LIMITED PRODUCT WARRANTY REGISTRATION CARD To validate the above warranties, ALL the following conditions must all be fulfilled: 1. The unit was fully (100%) and successfully installed by licensed or certified HVAC technicians. 2. The unit was installed following all NEC, state and local codes. 3. The unit was installed following all instructions and manuals made by YMGI Group. 4.
WARRANTY AND TECHNICAL SUPPORT IMPORTANT NOTES SAFETY WARNINGS YMGI warrants to the purchaser/owner(s) that YMGI products be free from defects in material and workmanship under the normal use and maintenance, with the standard Limited Product Warranty Policies that comes with the unit or sales package.
NOTICES FOR OPERATION The unit must be securely grounded. The cable shall be connected to the grounding device in the home or building. * Be sure to pull out the power plug when not using the air conditioner for a long time. NOTICES FOR OPERATION Select the most appropriate temperature. In case of any damage found on wires, must replace with good one without any delay. * The airflow direction can be adjusted appropriately, by adjusting the louvers of upward/downward and left and right accordingly.
NOTICES FOR USE INSTALLATION SERVICE-NOTICES FOR INSTALLATION BASIC REQUIREMENTS FOR INSTALLATION POSITION Principle: Install in the following place may cause malfunction. If it is unavoidable contact with service center please: Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
RECOMMENDED TOOLS FOR INSTALLATION INSTALLATION ILLUSTRATION 1) Mounting Indoor & Outdoor Units and Running Piping/Wiring Ruler (Not Shown) Stud-Finder Dry-Wall Saw Electric Drill 3" Hole Saw Drill Extension Hammer Drill and Bit (Not Shown) Measuring Tape Level Flash Light Screw Driver (Phillps and Flat) Hammer Knife Scissors Goggled Glass Mask Gloves Ladder Indoor unit Air Inlet Displayer Front Panel Wrapping Tape Wall Plpe Filter Guide panel Air wall sleeve 2) Refrigeration Related Work 3) Elec
INSTALLATION DIMENSION DIAGRAM INSTALL INDOOR UNIT INSTALL THE REAR PANEL OVER 2" Indoor unit A OVER 4" OVER 4" 1) Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and level should be 0 or more, that is good for condensing water drainage.
INSTALL INDOOR UNIT INSTALL PV-MODULE NOTE: When connecting the electric wire if the wire length is not enough, please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed. PV-MODULE CHARACTERISTICS Electrical Characteristics 33.4V Solar Cell Optimum Operating Voltage (Vmp) 26.2V No. of Cells 54 (6*9) Short - Circuit Current (Isc) 8.12A Dimensions 1482*992*35mm (58.3*39.1*1.
INSTALL PV-MODULE INSTALL PV-MODULE Assembly method Installation sketch Maximum number of PV-modules in one system: 5 PV-Module PV-Module PV-Module 0.24-0.3 inch.
INSTALL PV-MODULE INSTALL PV-MODULE INSTALLER'S INSTRUCTION INSTALLER'S INSTRUCTION CHECK AFTER INSTALLATION AND TEST OPERATION TEST OPERATION 1) Before test operation 1) Do not turn on power before installation is finished completely. 2) Electric wires must be connected correctly and securely. 3) Cut-off valves of the connection pipes should be back seated/tunned on. 4) All the impurities such as scraps and thrums must be cleared out of the unit.
REMOTE CONTROL-BUTTON NAME & FUNCTIONS CHECK AFTER INSTALLATION AND TEST OPERATION CHECK AFTER INSTALLATION NOTE1: This is a general use remote control. That can be used for numerous air conditioning model numbers. There may be some buttons on the remote that are not for use with the unit purchased. When these buttons are pressed you may hear a beep sound emitted from the remote. This will not affect the unit status. NOTE2: Be sure there are no obstructions between the indoor unit and the remote control.
REMOTE CONTROL-BUTTON NAME & FUNCTIONS "FAN" BUTTON: By pressing this button you can select from fan speeds AUTO→Low→Middle→High. When the unit is first powered on the default fan speed setting is AUTO. When running the unit in DRY mode the fan speed will only run in low speed. AUTO High fan High fan High fan Note: Under the Dry mode, the fan speed isn't adjustable, low fan speed is imperative. REMOTE CONTROL-BUTTON NAME & FUNCTIONS "CLOCK" BUTTON: The time function runs on a 24 hour clock.
OPERATION OF REMOTE CONTROL REMOTE CONTROL-BUTTON NAME & FUNCTIONS SYMBOL DISPLAY When power is first applied to the unit but the power has not been turned on by the remote control, then the red power light only is displayed. When the unit has been powered on by the remote control then the running LED is lit and the current running mode symbol is displayed at the same time. COOLING: Running symbol and cooling symbol are lit. HEATING: Running lamp and heating symbol are lit.
TROUBLE SHOOTING CLEAN AND CARE * Before cleaning the unit, turn power off by remote control and then disconnect the electrical power at outdoor unit. * Never sprinkle water on the indoor unit and the outdoor unit. * Volatile liquid (gasoline or the like) will damage the unit. (So wipe the units with a dry soft cloth, or a cloth slightly dipped with water or cleanser.) CLEAN THE FRONT PANEL Do not repair the air conditioner at your discretion.
TROUBLE SHOOTING Phenomenon Unit doesn't respond to remote control. CUSTOMER AND TECHNICIAN MUST READ WHY DOES YMGI GROUP REQUIRE INSTALLATION AND SERVICE TO BE 100% PERFORMED BY LICENSED OR CERTIFIED HVAC TECHNICIAN/ CONTRACTOR? Normal or Abnormal 1) Is the remote control our of battery power? 2) Is remote control pointing to sunshine or lighting? 1) They have the training and experience to accurately and safely install and service your equipment.
CUSTOMER AND TECHNICIAN MUST READ CUSTOMER AND TECHNICIAN MUST READ 11) If all the suggestions have been taken and all the necessary steps are followed. 12) If the contractor(s)/technician(s) are experienced with the systems/brands you purchase. You might spend less. But remember, many times you get what you pay for. 13) Sign a contract with them. The contract should list all the detailed work they will conduct and the standards they will follow.
CUSTOMER AND TECHNICIAN MUST READ CUSTOMER AND TECHNICIAN MUST READ C. YMGI must verify the following before you can pack your products: 1) No products (units, parts, accessories) are missing. 2) No damage is found. 3) The products are in the original packaging. 4) No duct tape on any product or box. 5) Pictures have been taken and sent to YMGI to verify the product and boxes are not damaged. 6) The RGA has been completed and a copy has been returned to YMGI, via email or fax.
CUSTOMER AND TECHNICIAN MUST READ USER NOTES AND INSTALLATION/SERVICE/MAINTENANCE NOTES Standard factory warranty does not cover the cost of materials and labor that are incurred at your site. USER NOTES There will be no cost for the replacement unit, if YMGI determines the defect is manufacturer related. Put down whatever questions you have or problems you have seen as a unit history: Replacement will be made with the same model, only. Alternate units will be treated as a new order. No.
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! P39 OF 40 YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World ! P40 OF 40