REFIT DRAIN HOSE FROM THE RIGHT TO THE LEFT SIDE
If the drain hose needs to be refitted from its original position
(right side) to left side of the indoor unit, careful handing is
necessary as not to damage the unit.
Refitting method: remove the drain hose from its original
position, without breaking the hose. Remove the plug at
the left side. Apply water-resistant glue to fit the drain
hose and the fitting before securing it.
Apply water-resistant glue onto the plug and fit it back
into the condensate connection at right side.
NOTES: One can use a clamp to further secure
the connections.
HANG INDOOR UNIT
Run copper set/wire cables/drain hose through the wall hole
and hang the indoor unit onto the mounting plate (place the
hook on the mounting plate into the hanging rib at rear side of
plastic casing).
Snap the plastic casing bottom into the mounting
plate, gently.