Service manual

IMPORTANT NOTES FOR UNIT OPERATION ABMIENT & SIZING
P15 OF 34
CONNECTION TUBE
ALLOWED MAXIMUM
REF. TUBE
WEIGHT
DIMENSION W H D
LOADING CAPACITY
DRAIN
REFRIGERANT
LIFT
DROP
TOTAL LENGTH
INDOOR-NET
INDOOR-GROSS
OUTDOOR-NET
OUTDOOR-GROSS
INDOOR-NET
INDOOR-BOX
OUTDOOR-NET
OUTDOOR-BOX
20'/40'/40'HQ
DRAIN PIPE
DISCHARGE
SUCTION
FT
FT
FT
LBs
LBs
LBs
LBs
INCH
INCH
INCH
INCH
SETS
OPTIONS AT MANUFACTURE OR AFTER SALES:
* Rust-free Cabinet
* Plug & Connect Valves
* Low Ambient Control
* Wall Mount Line Control
* Cabled Defrost Control
COMPRESSOR
ELECTRIC HEATER (SUP.)
DEHUMIDIFICATION
SEER
HSPF
SOUND LEVEL (Actual)
REFRIGERANT
TOTAL CURRENT
MCA
HVAC CIRCUIT
BREAKER SIZE
INDOOR FAN MOTOR
OUTDOOR FAN MOTOR
INDOOR / OUTDOOR
W/O HEATER (31,32 Models)
WITH HEATER (34 Models)
W/O HEATER (31,32 Models)
WITH HEATER (34 Models)
W/O HEATER (31,32 Models)
WITH HEATER (34 Models)
FAN
MOTOR (PSC)
FAN
MOTOR (PSC)
HERMETIC
AMP
AMP
AMP
AMP
AMP
AMP
TYPE
CFM H/M/L
RATED AMP
SPEED
TYPE
CFM
RATED AMP
SPEED
TYPE
BRAND
W(MAX)
PTS./H
BTU/H.W
BTU/H.W
dB(a)
HEATING BOOSTER(-34B MODELS ONLY)
RATED
RATED
RATED
PRE-CHARGED FOR 25' TUBING
FROM CIRCUIT BREAKER TO OUTDOOR TO INDOOR UNIT
POWER SOURCE
COOLING ONLY
HEAT PUMP
MODELS
MODELS
MODELS
HEAT PUMP+ELE. HEATER
System Model
System Model
System Model
REF. TUBE/WIRE INS. KIT
COOLING CAPACITY
HEATING CAPACITY
BTU/H 1), 2)
BTU/H 1), 2)
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Copper Sets, Wiring, Putty, Wall Sleeve, Wrap, Drain Hose
Rated ID 80/67F OD 95F
Rated ID 70/60F OD 47F (17F)
RECOMMENDED WORKING TEMPERATURE RANGES
RECOMMENDED WORKING TEMPERATURE RANGES
COOLING ID/OD (F) 3)
HEATING ID/OD (F) 3)
* Advanced Health Kits (HEPA/Enzyme/
Cold Catalyst Filter, Light Wave, Or,
Anion Generator)
* Treated Coil
* Plug & Connect Copper Line Set
3/8"
5/8"
25
25
75
37
46
150
172
49.5x12.8x9.1
52.0x16.3x12.8
34.6x31.1x14.2
40.6x35.5x18.9
48/98/116
1200
7.6
38-45 / 48-54
700/615/560
0.56
8.6
13.8
10.9
16.8
25.0
30.0
2350
0.90
WMMS-24K-31B
WMMS-24E-31B
WMMS-24C-31B
WMMS-24K-32B
WMMS-24E-32B
WMMS-24C-32B
WMMS-24K-34B
WMMS-24E-34B
WMMS-24C-32B
INST-3858-xx
24000
25000 (15360)
Flexible
1/4"
3/8"
25
25
50
20
25
57
65
31.5x11.5x7.8
34.3x14.4x11.0
27.6x21.3x10.0
31.5x24.4x14.8
108/228/258
1/4"
1/2"
25
25
50
24
28
81
89
33.9x11.5x8.0
36.6x14.4x11.0
31.1x21.3x9.7
35.2x24.4x14.0
102/220/242
3/8"
5/8"
25
25
65
33
44
110
121
42.5x13.0x8.7
46.5x16.7x11.9
33.3x26.8x12.2
39.8x30.1x16.9
66/138/148
800
3.4
1000
4.6
1200
6.9
13
9.2
26-34 / 42-51 28-38 / 43-51 32-41 / 46-53
R410A
A: 115/1/60 B: 208-230/1/60
CROSS FLOW
235/200/185
0.20
330/310/235
0.40
645/575/515
0.39
3
PROPELLER
1
ROTARY
6.9
10.4
8.9
13.0
15.0
20.0
8.1
12.4
9.5
15.0
20.0
25.0
6.4
11.6
8.8
14.5
20.0
25.0
1175
0.20
1175
0.50
1765
0.60
WMMS-09K-31A
WMMS-09E-31A
WMMS-09C-31A
WMMS-09K-32A
WMMS-09E-32A
WMMS-09C-32A
WMMS-09K-34B
WMMS-09E-34B
WMMS-09C-32B
INST-1438-xx
WMMS-12K-31A
WMMS-12E-31A
WMMS-12C-31A
WMMS-12K-32A
WMMS-12E-32A
WMMS-12C-32A
WMMS-12K-34B
WMMS-12E-34B
WMMS-12C-32B
INST-1412-xx
WMMS-18K-31B
WMMS-18E-31B
WMMS-18C-31B
WMMS-18K-32B
WMMS-18E-32B
WMMS-18C-32B
WMMS-18K-34B
WMMS-18E-34B
WMMS-18C-32B
INST-3858-xx
9000 12000 18000
9500 (6120) 12800 (7780) 19000 (11350)
Indoor Side 61 to 105 / Outdoor Side 45 to 115 4)
Indoor Side 17 to 86 / Outdoor Side 17 to 75 5)
Hitachi, Sanyo, Panasonic
1) Performance rated for matched system at standard conditions-cooling ID 80/67F, OD 95F, heating ID 70/60F, OD 47/43F. Unit performance
varies when weather changes from the standard one.
2) Select equipment capacity/sizes per space load calculation schedule at local design temperatures and cooling & heating hours. Not to
over size or under size equipment.
3) Watch unit operation during extreme weather conditions in summer and winter. After the unit is used for quite a while in these weather, unit
may step into protection mode and stay idle.
4) May work in lower temp if installed with optional low ambient controller. Ref. ICM 326HN.
5) Capacities and efficiency decrease, as outdoor temperature drops.
P16 OF 34
A) The indoor fan runs at low speed.
o
B) After one hour of operation the set temperature will decrease by 36 C . One hour later, the set temperature will
oo
decrease by 2 C once more. The unit will then continue operating at 39 C below the set temperature.
A) The indoor fan runs at low speed.
B) After one hour of operation the set temperature will increase by 34 . One hour later, the set temperature will
increase by 1 once more. The unit will then continue operating at 36 above the set temperature.
o
C
oo
CC
Sleep mode in heating running
Sleep mode in cooling and drying running
SLEEP MODE
FAN MODE
* Indoor fan runs at the set speed while compressor and outdoor fan are turned off.
* Indoor fan speed can be adjusted for low, medium and high.
* Auto mode entering
a) Once some operation mode is determined, it can not be changed even if the RT has altered.
b) You can change the operation mode by remote controller.
* If restart within 2 hours, the unit will resume the same operation mode as before.
If restart after 2 hours, the unit will select the operation mode according to the initial room temperature.
* At auto mode the ST can only be set + or - 2 of the RT.
* In this mode, the air conditioner can automatically adjust the room temperature to decide the most suitable
temperature. At the start of operation, the unit will automatically select the operation mode according to the
room temperature. The following table shows the conditions which are set at start up.
AUTO MODE
d) In this mode, the indoor fan keeps running at low speed with the same pace as the compressor, and this
speed can not be controlled by remote controller.
* In this mode, the air conditioner automatically sets the room temperature and this temperature is incontrollable
by remote controller. The initial ST=RT-2 .
* Control during dry mode:
DRY MODE
a) When RT<15 , dry mode is not available; when RT 15 , the compressor intermittently runs under the
influence of TS and RT.
b) When RT 23 , if RT ST, the compressor runs intermittently as this: Run for 8 minutes Stop for 3 minutes
If RT<ST, the compressor runs intermittently as this: Stop for 4 minutes Run for 1 minute
c) When RT<23 , if RT ST, the compressor runs intermittently as this: Run for 2 minutes Stop for 3 minutes
If RT<ST, the compressor runs intermittently as this: Stop for 4 minutes Run for 1 minute
CONTROL SPECIFICATION
Room
Temperature (RT)
Cool only type
Mode Mode
Cool Cool
Dry Dry
Initial Setting Temperature
o
RT 79 F
o
79 F>
o
RT 77 F
o
77 F>
o
RT 73 F
o
RT<73 F
o
75 F
o
75 F
o
70 F
o
79 F
RT-2 RT-2
RT-2 RT-2
Heat pump type
Initial Setting Temperature
YMGI, A COMFORT MAKER, A JOY COMPANION, A SATISFACTION GUARANTOR... YMGI, A COMFORT MAKER, A JOY COMPANION, A SATISFACTION GUARANTOR...