* To be installed at the position where the air delivered from the unit can reach every comer of the room.
* To avoid being affected by the outdoor air.
* To avoid blockage to the air inlet or outlet of the unit.
* To avoid too much oil smoke or steam.
* To avoid possible generation, inflow, lingering or leakage of flammable gases.
* To avoid high-frequency facilities (such as high frequency arc welders, etc.).
* To avoid the places where acid solutions are frequently used.
* To avoid the places where some special sprayers (sulfides) are frequently used.
* Not to install on top of the musical instruments, TV, computer etc. valuable appliance.
* Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm device might
be erroneously triggered by the warm air from the unit).
HEIGHT LIMITS OF INDOOR AND OUTDOOR UNITS
* Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated r
equirements.
* Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon
the performances of the units.
Indoor unit
Outdoor unit
Lift
* Make P-trap if elevation drop difference is more than 25", as illustrated below.
Indoor unit
Outdoor unit
Drop
P-Trap
18 Ft.
Refrigerant Pipe Min/Max. Length, Rise and Drop Height
1,000 Btu/h
09-12
18-24
30-36
Max. Length (Ft.)
50
75
100
Max. Rise Height (Ft.)
20
25
35
Max. Drop Height (Ft.)
28
35
50
Min. Length (Ft.)
15
15
15
P20 OF 34
Locate the central hole at the stud (firn structure)
At least 12
inches
18" or more
from sidewall
Respect the slope
Plumb
Mounting Plate
Anchors of self-
tappping screw
18" or
more from
sidewall
Install Mounting Plate and Drill Hole for Combination of Copper Line/Wire Cable/Drain Hose
NOTES:
Anchors must be put into the holes, where the solid
arrows are pointing, as shown above, to secure the
mounting plate firmly and to hold the weight of indoor
unit. If more screws/anchors are to be used, make
sure to keep the two holes close to each other, at
least 2 inches apart.
Mounting plate should be attached to the structural
part of the wall. Minimum clearance, as shown below,
is required in order to ensure proper airflow and
enough service room.
DURING INSTALLATION-INDOOR UNIT
INSTALL WALL MOUNT PLATE
If pipes need to come out of the right side (facing
the front of indoor unit) of the indoor unit, snap off
portion 1 on plastic casing.
If pipes need to come out of the bottom side
(facing the front of indoor unit) of the indoor unit,
snap off portion 2 on plastic casing.
If pipes need to come out of the left side (facing
the front of indoor unit) of the indoor unit, snap off
portion 3 on plastic casing.
* Check unit to make sure the unit is good shape and ready to install.
* Check to make sure the installation location is firm enough to hold the weight of the whole unit and is
convenient to installation, maintenance, service and close to the indoor unit but not causing noise or airflow
issues to neighbour.
* Install Indoor unit. Enough anchor bolts/nuts shall be used to secure mounting plates for indoor units.
Brackets should be at level position.
Mark drill positions. At least 4 anchor holes, one at each perimeter corner of the plate are needed to secure the
plate, where the bold arrows are pointing, as shown in the picture above. Refer to the specification sheet for
unit weight so that enough anchors are installed at proper positions.
Pre-drill guiding holes where are marked for anchors or screws on the wall
Confirm the position of the holes and finish drill to the depth needed for anchors (NOT for screws)
Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to
secure mounting plate.
STEPS TO MOUNT PLATE:
Hole Diameter: 2.5~3 In
Align ruler with straight line
Insert ruler
DRILL 3IN HOLE FOR PIPING/WIRING/DRAIN
Locate the centre where the hole will need to
drilled.
Drill the holes of 2.5-3Inch diameter. A down pitch
about 1/4" per foot, as illustrated below, is needed
for the hole, in order to drain the condensate
properly.
PREPARE INDOOR UNIT- COPPER LINE SET/DRAIN HOSE
a
b
c
Drill mounting holes
to make sure at least
either one of three
dimensions a, b and
c is 16" center to
center.
1
2
3