Specifications
PRODUCT
SPECIFICATIONS (56)
1716
Symphony
SOLAR
•••••
MINI SPLIT DC INVERTER
(56)-PV BOOSTED DC INVERTER
SOLAR (56)-PV Boosted-Solar Panel
The SOLAR (56) PV Boosted DC Inverter
incorporates a photovoltaic (PV) type solar
panel, which generates DC current that can be
used to replace or augment the use of standard
AC current. One or more PV solar panels can be
installed in series, as long as the recommended
voltage/current specification requirements are
followed before being connected to the outdoor
unit terminals. PV panels are most commonly
installed on rooftops, and are most eective with
a southern exposure that provides full sunlight.
Other possible installations include a ground
mount or a pole mount.
SOLAR (56)-PV Boosted DC Inverter
Wall Mounted Indoor Unit
The SOLAR (56) single zone mini split wall
mounted unit, as the most popular evaporator
style, oers a heating and cooling solution that
runs quietly and fits tastefully into any single
room application. The installation of the indoor
unit uses an integrated mounting plate and only
requires a 3” opening through the wall to run a
conduit, which houses all necessary condensate
drain hose, refrigerant pipes and electrical wiring.
Unit mounts high on the wall, out of sight.
SOLAR (56)-PV Boosted DC Inverter
Outdoor Unit
The SOLAR (56) outdoor condensing unit takes
electrical power from the disconnect switch for
most residential and commercial heating and
cooling applications. It provides electric power
to both the outdoor and indoor unit. Refrigerant
is pumped as a thermal medium to dispense
heat into ambient air in summer while absorbing
heat from ambient air in winter. The sleek design
allows mounting in a variety of discreet locations,
including on the ground, on the wall, under decks
or even on balconies.
WMMS-09KS-V2B(79)
WMMS-09ES-V2B(79)
WMMS-12KS-V2B(79)
WMMS-12ES-V2B(79)
WMMS-18KS-V2B(79)
WMMS-18ES-V2B(79)
WMMS-24KS-V2B(79)
WMMS-24ES-V2B(79)
WMMS-36KS-V2B(79)
WMMS-36ES-V2B(79)
Model
Power Supply
208-230V/1Ph/60Hz 208-230V/1Ph/60Hz
Performance
Capacity at
Rated Indoor
and Outdoor
Temperature
Conditions
9000 12000
2600 3500
10000 13000
2900 3800
Noise Level
26-30 26-30
50 50
Air Circulation 300 430
EER
SEER
16.5
(Up to) 28 (Up to) 28 (Up to) 26 (Up to) 26 (Up to) 24
16.4
COP
Recommended Outdoor Ambient Ranges
5.2 5.1
Power
Input Power
at Rated
Conditions
536 726
563 752
Input Current
at Rated
Conditions
2.4
3.3
2.6 3.4
Units-Dimensions (W*H*D)
Indoor Unit
33.3*12.8*9.0 39.8*12.8*7.9
35.6*14.6*11.1 41.9*14.8*10.0
Outdoor Unit
32.3*12.6*21.3 36.6*13.0*23.6
34.8*14.2*23.6 39.2*15.4*25.6
Units-Weight
Indoor unit 25.4/29.8 33.1/40.8
Outdoor unit 83.8/83.8 112.4/123.5
Solar Panel
Dimensions
(W*H*D)
Weight
Cooling
Btu/h
W
Heating
Btu/h
W
Indoor
db(A)
Outdoor
db(A)
CFM
Btu/h.W
Btu/h.W
W/W
F AC 15 to 115 HP 5 to 86
Cooling
W
Heating
W
Cooling
A
Heating
A
Net Inch
Shipping
Net
Shipping
Net/shipping
LBs
Net/shipping
Net/shipping
Net/shipping
208-230V/1Ph/60Hz 208-230V/1Ph/60Hz
18000 24000
5000 7000
19000 26000
5500 7800
26-31 26-32
52 60
500 580
16.5 16.2
5.1 5.1
1030 1512
1080 1523
4.7 6.9
4.9 6.9
42.9*12.8*8.7 65.0*14.6*10.2
46.1*15.6*11.8 67.7*17.3*12.6
36.2*14.8*28.7 39.4*16.1*37.8
40.4*15.6*35.0 42.5*17.1*41.7
39.7/48.5 70.6/83.8
134.5/145.5 165.4/187.4
208-230V/1Ph/60Hz
36000
10000
38000
11000
28-34
62
760
15.4
4.6
1240
1270
5.6
5.8
65.0*15.0*10.6
66.9*16.5*12.8
38.6*14.6*52.2
42.7*17.1*56.3
88.2/99.2
260.6/277.8
30.9/35.330.9/35.3
Inch
Inch
Inch
LBs
LBs
Inch
39.4*21.7*3.439.4*21.7*3.4
System
Indoor Unit
Outdoor Unit
Solar Panel
WMMS-09CS-V2B(79)
WMMS-09PS-V2B(79)
WMMS-12CS-V2B(79)
WMMS-12PS-V2B(79)
WMMS-18CS-V2B(79)
WMMS-18PS-V2B(79)
WMMS-24CS-V2B(79)
WMMS-24PS-V2B(79)
WMMS-36CS-V2B(79)
WMMS-36PS-V2B(79)
30.9/35.330.9/35.330.9/35.3
39.4*21.7*3.439.4*21.7*3.439.4*21.7*3.4










