Technische gegevens LRP NT plus (gas E, low NOx)
LRP NT plus 1234567891011121314
Vermogens
Nuttig vermogen qN (80/60°C)
max. 65 85 110 135 150 170 210 230 250 275 325 400 450 500
min.
3
25 26 36 41 43 48 54 52 58 70 78 91 103 125
Warmtebelasting qF
max. 70 93 119 146 162 185 228 250 271 297 353 433 488 542
min.
3
26 28 38 43 45 50 56 54 61 73 81 95 107 130
Modulatie
80/60°C 37% 30% 32% 29% 28% 27% 25% 22% 23% 25% 23% 22% 22% 24%
@ tm=40°C 60% 51% 53% 47% 45% 45% 45% 44% 47% 50% 48% 48% 48% 52%
Rendementen
Thermisch rendement 60 / 80 °C
100%
%
92.3 91.8 92.5 92.0 92.3 92.0 92.0 92.2 92.1 92.5 92.0 92.5 92.2 92.2
Thermisch rendement @ tm=40 °
C
30%
3
%
95.7 95.8 95.9 95.9 96.0 96.1 96.1 96.1 96.1 96.1 96.1 96.2 96.2 96.2
Rendement DIN4702-8, 60 / 75 °
C
η
N
%
94.4 94.5 94.6 94.6 94.7 94.7 94.7 94.7 94.8 94.9 94.9 94.9 95.0 95.3
Debieten
Gasdebiet, gas E (G20)
max.
1,2
7.1 9.3 11.9 14.7 16.3 18.5 22.9 25.1 27.2 29.8 35.4 43.4 49.0 54.4
min.
1,2
2.6 2.8 3.8 4.3 4.5 5.0 5.7 5.5 6.1 7.4 8.1 9.5 10.8 13.1
Rookgasdebiet
max. nat 0.03 0.04 0.05 0.06 0.07 0.08 0.10 0.10 0.11 0.12 0.15 0.18 0.20 0.23
min. nat
3
0.01 0.01 0.02 0.02 0.02 0.02 0.02 0.02 0.03 0.03 0.03 0.04 0.04 0.05
Rookgasgegevens, verliezen
Druk verbrandingskamer
max.
mbar
0.38 0.79 0.84 1.41 1.48 2.13 1.92 1.78 2.36 1.89 2.94 2.06 2.93 4.27
Rookgastemperatuur bij 80/60 °C
max. 168 182 168 179 174 180 181 178 179 170 182 172 177 178
min.
3
Rookgasverliezen bij 80/60 °C
max.
%
7.0 7.7 7.0 7.6 7.3 7.6 7.7 7.5 7.6 7.2 7.7 7.2 7.5 7.6
Stilstandverliezen qB
70 °C
W
343 343 442 442 451 451 539 552 552 659 659 779 779 779
Hydraulische gegevens
Waterweerstand
t=10K
37 64 33 50 63 80 42 51 60 73 102 67 85 104
t=20K
9 16 8 13 16 20 11 13 15 18 26 17 21 26
Waterdebiet
max. 5.6 7.3 9.5 11.6 12.9 14.6 18.0 19.8 21.5 23.6 27.9 34.4 38.7 43.0
Bedrijfstemperaturen
max.
TVB
Gegevens volgens EN303-3 bij:
3zugskessel, V-07/06
- lamda=1.15, CO2=10%
GB
- T-Lucht=20°C, rel. hum.=60%, p-baro=100kPa
1: Hi = 9.97 kWh/nm3
2: nm3 bij 0°C, 1013 mbar
3: S max = 10 mg / nm3
95
110
90
°C
m3/h
mbar
°C
kW
kW
kg/s
nm
3
/h
tm = 70°C
90
100
110
120
130
140
150
160
170
180
190
0 50 100 150 200 250 300 350 400 450 500
QN [kW]
[°C]
65
75
85
95
105
115
125
135
145
155
165
[°C]
GB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
tm = 40°C
Temperaturen rookgassen LRP NT Plus, low-NOx met aardgas bij schone ketel
tm = gemiddelde keteltemperatuur (zie ook par. 4.6.1)
Maat- en constructiewijzigingen voorbehouden! 10 editie 16.7.2007