2959 ROW UNIT MOUNTED FERTILIZER COULTER OPERATOR’S / INSTRUCTION MANUAL W/ PARTS IDENTIFICATION MANUAL PART# 2565-482_REV_B – LAST UPDATED: 04/09 YETTER MANUFACTURING CO. FOUNDED 1930 COLCHESTER, IL 62326-0358 TOLL FREE: 800/447-5777 309/776-3222 (FAX) WEBSITE: WWW.YETTERCO.COM E-MAIL: INFO@YETTERCO.
FOREWORD You’ve just joined an exclusive but rapidly growing club. For our part, we want to welcome you to the group and thank you for buying a Yetter 2959 Coulter. We hope your new Yetter implement will help you achieve both increased productivity and increased efficiency so that you may generate more profit. This operator’s manual has been designed into six major sections. Foreword, Safety Precautions, assembly instructions, Operation, parts identification and troubleshooting.
SAFETY A brief description of signal words that may be used in this manual: CAUTION: Used as a general reminder of good safety practices or to direct attention to unsafe practices. WARNING: Denotes a specific potential hazard. DANGER: Denotes the most serious specific potential hazard. SAFETY PRECAUTIONS You can make your farm a safer place to live and work if you observe the safety precautions given. Study these precautions carefully and insist that those working with you and for you follow them.
GENERAL INFORMATION The 2959 Fertilizer Coulter can be used as a R.H. opener or a L.H. opener, it is recommended that half of the planter is R.H. assemblies and the other half is L.H. assemblies. NOTE: The 2959 Fertilizer Coulter is NOT recommended for use in rocky conditions as the coulter arm and fertilizer tube are susceptible to bending. For proper operation of the 2959 coulter, a ¼” NPT “Straight Stream” nozzle or a ¼” NPT Female “Nozzle Body” with orifice plates will be required.
ASSEMBLY INSTRUCTIONS STEP 1. Attach the 2959-203 fert. coulter faceplate w.a. to the planter unit using 3) ½-13 x 1 ½” bolts, flat washers and locknuts. Use the 1 ¾” OD x ¼” thick washer on the lower large slot. On some planter units, this washer may need to be trimmed enough not to interfere with a gusset. Center the bracket on the row unit and tighten the bolts to specification listed on the table on page 4. STEP 2.
ASSEMBLY INSTRUCTIONS STEP 3. Depth settings are in reference to the planter frame being level (front to back) when in planting position. Depth settings are in relationship to the planter disc opener blades being 15” in diameter and the fertilizer coulter blade being 16” in diameter. The coulter blade has 6 adjustment settings in a 2” range, with a maximum operating depth of 4” below the surface.
ASSEMBLY INSTRUCTIONS STEP 5. At the pipe coupler install the appropriate nozzle (not supplied) according to the liquid fertilizer application rate. Nozzles can be ordered through your nearest implement dealer or fertilizer equipment dealer. See the tip application chart in this manual. STEP 6. Attach the coulter blade to the arm/hub assembly using 4) ½-13 x 1 ½” carriage bolts, lock washers and hex nuts.
OPERATION PRECAUTIONS STOP Read this before using the Yetter product. - MACHINE OPERATION IMPORTANT: failure to properly set the planter frame height and levelness can result in less than successful operation of the planter and the Yetter product and may result in damaged equipment. All operators should read and thoroughly understand the instructions given prior to using the Yetter product.
PLANTER ADJUSTMENT 9
PARTS IDENTIFICATION 10
TROUBLESHOOTING Problem Row unit floats out of soil Planter pulls to one side Cause Insufficient down pressure Solution Increase the tension of the planter unit down force springs Planter frame not level for and aft Level the frame at 20” frame height while in planting position Soil too hard/compacted May have to use a tillage implement to loosen soil 2959 fertilizer coulter blade adjusted too deep Raise the coulters.
LIQUID FERTILIZER APPLICATION RATE AND PRESSURE CHART TABLES ARE BASED ON 30” NOZZLE SPACING GPA = (Per Nozzle) 5940 X GPM MPH X W H20 = WATER SOLUTION FACTOR GPA = GALLON PER ACRE 28% = H20/1.13 GPM = GALLON PER MINUTES 32% = H20/1.15 MPH = MILES PER HOUR W = WIDTH This table is a reference only. Please calibrate your equipment to insure proper rate of application. The information contained in this issue is offered in good faith by Yetter Mfg. Co.