User Manual
General settings:
The controller has a fixed setting the throttle curve (throttel curve), so they are linearly
linked to all conventional transmitter and drawers. With all programmable transmitters,
"throttle range) should be set to the default (+ 100%), trim set to zero and the "throttle
trim" ???? released. However, necessary with some transmitters that this area has been
leveled. Because of these "throttle endpoints" must trim set so that the notch (pass) before
the lowest position of the lever stops the motor and notch (pass) before gives full power
engine at full power. LED indicates that full power is completely off.
The timing is adjusted to 18 °, the brake is set at a medium level and detecting
undervoltage
adapted to Lipo mode 3.1 V
If during cranking rpm detected any abnormalities (it will be irregular sound), the timing
must be increased. If even at 30 ° there is no improvement, then the motor is overloaded.
In this case, help one cell smaller battery or a stronger motor. If after the engine stops, you
hear 2 repeating beeps. This means that the battery voltage dropped below the set value.
Alternatively, try cut off (disable, interrupt) voltage of 2.9 or 3.0V per cell. If still no
improvement, then the battery is dead or too weak, wires are too long or too small or plug
is out operation. If you brake is activated, you hear these warning tones only in the position
of open gas. This is small area to "throttle" lever between the brake and start the engine.
This position can reach 2 mA
Steps of or with high turnover and short gas start.
If you do not have an automatic timing can be adjusted according to the following
instructions.
If your engine manufacturer recommends setting the timing, it is better to set.
Basic rule: the higher the better timing performance full rpm.
It is easiest to make these changes with ProgCard II. There is a possibility to make
adjustments to the transmitter;
However, it will not be explained here. You can find it in the RC-setup manual for
www.yge.de tab Dowlnoad.
Take note that a complete set can only be done using ProgCard II.
In the event that inadvertently get into programming mode during start (throttle stick to full
power), simply disconnect the battery, turn the lever to stop position and reconnect the
battery. That fall do not have to be adjusted again.
setting helicopters
For helicopters in governor mode must be a full range of gas once calibrated. For some, this
transmitter
one indicated in the helicopter menu (throttle curve 0-100%). The "curve" will then coincide
with the
gas regulator from 0-100%. Please refer to the ProgCard or RC-setup manual.
If you activate one of the governor modes, all relevant parameters helicopters are set to
standard. This default setting will fit all settings. There is no need for further adjustment in
first step.
The list of standard setting:
Timing = 18 ° C