User Manual
YEP 18A ESC
Specifications:
- Given current is the maximum continuous full executive power with adequate cooling
- 2 to 6S LiPo, with undervoltage protection.
- 6-18 NiMH cells, with undervoltage protection.
- The possibility of disconnection when detecting undervoltage
- SBEC Output: 5.5V, 3A permanent, 5A max
- Governor Mode
- Soft Start
- Active idle, allowing unlimited / partial load
- Automatic or 6x step adjustable timing
- Continuously adjustable (adjustable) F3A brake
- 3-step adjustable brake EMF
- Switching interval: 8 to 16kHz
- Speed limit: 240,000 RPM (2-pole motors)
- Temperature control and overload
- A circuit that prevents sparks: reduces sparking when connecting
- Programming with ProgCard II (the program card)
Initial setting:
After connecting the battery (red (red) = plus, black (black) = minus) you hear 3
descending tones. Then you hear a series of beeps, depending on the cell number of the
connected Lipo battery.
If the transmitter throttle stick is in the "off throttle”, you will hear 3 rising tones.
It is necessary to connect the motor to hear the beep, since the motor itself acts as a
speaker.
--- The controller is now ready for use ---
If the motor runs in the opposite direction, simply replace 2 of the 3 motor connectors.
Use only clean and solid gold connectors for motor and battery. PK 3.5-mm connectors are
the best choice from 30 to 80 A. Be careful to choose the correct polarity security system
battery connector. Replace sparking or corroded connectors. Because only if these are in
order and will have the correct contact, then they can ensure lasting leadership to prevent
regulator worked properly. If you type 120A and 160FAI please use 5.5 and / or 6 mm PK
gold connectors, 3,5 and 4 mm because connectors are verified (suitable) only to 80A.
Motor cables are usually truncated to a minimum and soldered exactly that seats on the
engine. On the other hand, all ESC types, the total length of the cable from the controller to
the battery should not exceed 20 cm. If need longer cables, Low ESR 330μF capacitor
switching / 25Vby should be every 20 cm soldered between plus and negative lead. It is
possible to consider using our capacitor type YGE Cap's fifth Similar cables signal can be
extended. In this case, please use twisted-pair cables to minimize jamming.
Note: The rollover polarity battery causing severe damage and void the warranty.