Operating instructions
17
Installation Checklist
Freestanding Installation
5
C
B
A
A
150
150
Non Combustible Material
Combustible Materials
4.3 It is essential for safety to ensure the following clearances to
combustible materials are maintained.
See Diagrams 3 & 4 and table below.
Model D (side) E (Rear) F (Above)
Exmoor 400 400 N/A
Exe 500 500 N/A
Devon 500 500 N/A
County 450 650 N/A
5. Optional Extras
Smoke Control Kit
Some appliances can be modified to burn wood in a smoke
control zone. For more details on the Smoke Control Kit for
this appliance contact your retailer.
NOTE: These appliances have been independently tested to
PD6434 and have been exempt from the controls that
generally apply in smoke control areas hence are
considered suitable for use in Smoke Control Area when
burning wood and ONLY when fitted with the relevant
Smoke Control kit .
See User Section 15 - Optional Extras
Multi-fuel Grate
To burn wood and smokeless fuels efficiently in a
woodburning appliance a cast iron multi-fuel kit must be
fitted. This also allows the efficient combustion of wood.
See User Section 15 - Optional Extras