Operating instructions
16
Installation Checklist
3. Minimum Dimensions - Hearth
3.1 The appliance must stand on a non-combustible
constructional hearth which is at least 125mm thick with the
minimum dimensions as shown in Diagram 2.
150mm
minimum
840mm
minimum
840mm
minimum
150mm
minimum
150mm
minimum
225mm
minimum
2
Constructional
Hearth
Decorative
Hearth
3.2 If this appliance is installed in an elevated setting it is
recommended to increase the 225mm hearth depth to safely
contain any falling logs or embers. The higher the appliance
is installed the deeper the hearth should be to avoid
scorched floor coverings.
4. Clearances
IMPORTANT: INSTALLATION MUST COMPLY WITH
CURRENT BUILDING REGULATIONS
ENSURE THAT SUFFICIENT CLEARANCES ARE
PROVIDEDBETWEENTHEFLUEPIPEANDANY
COMBUSTIBLE MATERIALS IN THE FIREPLACE IN
ACCORDANCE WITH THE RULES IN FORCE.
†
.
.
4.1 When installing a Yeoman stove it is important to observe
the following clearances to both combustible and non-
combustible materials.
Also ensure that a clearance of 1 meter is maintained in
front of the appliance when operating.
Fireplace: Minimum Clearances Above
& to the Sides
Combustible Materials
Non-Combustible Materials
Floor
Hearth
A
A
F
D
3
B
Fireplace: Minimum Clearances to
the Rear
Combustible Materials
Non-Combustible Materials
Floor
Hearth
A
E
4
B
Non-Combustible Materials
4.2 All appliances will require some clearance between them
and any non-combustible materials to allow for either:
— Installation, servicing or accessing controls.
— Convection in order for the appliance to function properly.
Minimum clearances for installation/servicing/convection is:
Rear - 25mm Sides 50mm Top 100mm
NOTE: If the non-combustible surface is less than
200mm thick additional clearances may be required.
This requirement ensures that the non-combustible material
does not transmit excessive heat through the wall onto
combustible material which might be placed against it.
See Diagrams 3 & 4 (Fireplaces)& Diagram 5
(Freestanding) and table below.
Distance to Non-combustible Materials
Distance of
Appliance to Wall
(A)
Minimum
Thickness of wall
(B)
Minimum Height of
Wall (C)
0mm - 50mm 200mm Height of appliance
+ 300mm OR
1200mm from the
hearth (take largest
dimension)
51mm - 300mm 75mm
300mm+ No requirement No requirement