Operating instructions
15
Installation Checklist
2. Essential Information
GENERAL
Model:
Exmoor
Exe
Devon
County
Exmoor
Exe
Devon
County
Nominal Heat Output
Wood kW 4.9 4.9 9 13
Solid Fuel kW
4.9 4.9 9 13
Efficiency
Wood % 78 78 81 78
Solid Fuel % 85 85 78 84
CO @ 13% O
2
Wood % 0.29 0.41 0.24 0.25
Solid Fuel % 0.17 0.35 0.19 0.22
Weight Kg 65 105 112 160
Recommended Fuels
Wood
Seasoned Wood (less than 20% moisture content)
Solid Fuel
Briquette smokeless fuel suitable for closed appliances
(Ancit-Phuracite-Taybrite-Homefire Ovals)
As tested to the requirements of EN 13240 for intermittent operation
Flue/Chimney Size
‡
May be reduced to 128mm (5")
if burning approved smokeless
fuels or burning wood in an
appliance approved for use in a
DEFRA smoke control area
Without flue liner Round (Diameter)
mm
‡
153 153 153 153
inch 6 6 6 6
Without flue liner system (Square)
mm 135 135 135 135
inch 5
1
/
2
5
1
/
2
5
1
/
2
5
1
/
2
FLUES
With Liner of Factory made system
(diameter)
installed in accordance with manufacturers
instructions
mm 153 153 153 153
inch 6 6 6 6
Flue/Chimney
minimum height**
All products
**must be 4.5m from the hearth to the top of the
flue, with no horizontal sections and a maximum
of 4 bends. Bends must have angles of less than
45 degrees from the vertical.
m 4.5 4.5 4.5 4.5
feet 15 15 15 15
Flue Draught
Min
mm Wg
1.0 1.0 1.0 1.0
Nominal 1.25 1.25 1.25 1.25
Max 2.0 2.0 2.0 2.0
Flue Gas Mass Flow
Wood g/s 5.8 4.7 4.9 9.5
Solid Fuel g/s 3.9 4.8 6.8 7.5
Flue Gas Temperature at
Spigot/Socket
Wood
o
C 338 394 426 340
Solid Fuel
o
C 338 394 426 326
Flue Outlet Size
(Top or Rear Option)
All
mm 128 153 153 153
inch 5 6 6 6
European Min Spec for Chimney Flue - T400 N2 D 3 G50
VENTILATION
A) Traditionally Built Homes
•Whereleakageisgreaterthan5m
3
/hour/m
2
.
•Ventilationnormallyrequired=550mm
2
per kW output over 5kW
B) Modern Construction Homes
•Whereleakageislessthan5m
3
/hour/m
2
.
•Ventilationnormallyrequired=550mm
2
per kW
A Additional Ventilation
mm
2
None None 2200 4400
cm
2
None None 22 44
in
2
None None 3.5 7.1
B Additional Ventilation
mm
2
2695 2695 4950 7150
cm
2
26.9 26.9 49.5 71.5
in
2
4.3 4.3 7.9 11.5
For full technical details on ventilation see Technical Appendix on Page 32