Specifications
ADVICE ON HANDLING AND
DISPOSAL OF FIRE CERAMICS
The fuel effect matrix and coals in this appliance are
made from Refractory Ceramic Fibre (RCF), a material
which is commonly used for this application.
Protective clothing is not required when handling these
articles, but we recommend you follow normal hygiene
rules of not smoking, eating or drinking in the work
area and always wash your hands before eating or
drinking.
To ensure that the release of RCF fibres are kept to a
minimum, during installation and servicing a HEPA
filtered vacuum is recommended to remove any dust
accumulated in and around the appliance before and
after working on it. When servicing the appliance it is
recommended that the replaced items are not broken
up, but are sealed within heavy duty polythene bags
labelled as RCF waste.
RCF waste is classed as stable, non-reactive hazardous
waste and may be disposed of at a licensed landfill site.
Excessive exposure to these materials may cause
temporary irritation to the eyes, skin and respiratory
tract; wash hands thoroughly after handling the
material.
1. SERVICING INSTRUCTIONS
The following outlines only the minimum work that
should be performed on an annual basis. This service
work, like any other work on the appliance, must only
be done by a qualified and competent engineer who is
registered with CORGI.
a) Open the door. This is achieved by first un-screwing the
cast handle to reveal an M6 nut, un-screw the nut, and
door will open.
b) Remove all coals and matrix from top of burner.
c) Remove ceramic mat from top of burner and discard.
d) Remove any debris from the top of the burner using a
vacuum cleaner and brush.
e) Inspect the burner unit.
f) Perform an ignition check.
g) Perform a flame failure check
h) There should be no need to service the burner. If
however this is required, then the engineer should
check the setting pressure at inlet to burner; the correct
pressure is shown on the data information plate.
i) Fit new ceramic mat. Brush off and replace coal
arrangement as shown on pages 12-14, replacing any
broken or damaged pieces.
j) Check all seals on door (including glass) and close the
Door.
k) Check the installation for gas leaks.
l) Check flue for clearance of products of combustion. If
any parts need to be replaced use only genuine Yeoman
parts, non-standard parts will invalidate the guarantee
and may be dangerous.
2. TROUBLE SHOOTING
A) The gas pilot will not ignite or stay lit?
i) Ensure the gas is turned on at the appliance and the
meter/cylinder.
ii) Depress the control knob for at least twenty seconds
once the pilot is alight to ensure the operation of the
safety thermocouple valve.
iii) Ensure that the pilot injector is not obstructed or
blocked and it is free from any dust or dirt.
iv) Ensure that the thermocouple has not been damaged in
transit. This is a very delicate Electro-magnetic device.
v) On propane, the cylinder could be empty.
B) The pilot is not burning or performing correctly?
i) Ensure the pilot flame is the correct size for the type of
gas. The flame should be focused on the thermocouple
probe.
ii) The pilot flame will have been set correctly in the
factory.
C) The Main Burner does not seem to be burning
correctly?
i) Ensure adequate gas pressure to the appliance. The
pressure can be checked by unscrewing the pressure test
nipple and applying a suitable pressure gauge (i.e. a
manometer). Ensure adequate volume of gas is being
used. Once the fire is burning on maximum, turn off all
other gas appliances in the house and calculate the fuel
being burned from the gas meter.
ii) Make sure that the burner is burning correctly. The
flame should be even across the top of the burner before
any coals are placed on top.
D) Optional Remote Control will not function.
i) Check PP3 battery in the handset is fully charged, if
not, change battery. Check the four AA batteries in the
receiver box are fully charged, if not, replace them.
3. SHORT SPARES LIST
Only original Yeoman parts may be used when replacing
parts on this appliance.
Exminster Nat Gas & LPG Matrix Set YM-YA75142
Exminster Nat Gas & LPG Log Set YM-YA75542
Exminster Ceramic Mat YM-YG75131
Exminster Mertik Gas Tap Nat Gas YM-YG75304
Exminster Mertik Gas Tap LPG YM-YG75305
Exminster Nat Gas Injector YM-YG75077
Exminster LPG Injector YM-YG14177
Exminster ODS Nat Gas Oxy Pilot Assy YM-NG9043
Exminster ODS LPG Oxy Pilot Assy YM-LPG9228
Mertik Ignition Lead YM-GC0090
Remote Motor Unit YM-EL0234
4 Sided Twin Door Glass 222x168mm GL0240
Single Door Glass 384x237x974R GL0241
INSTALLATION INSTRUCTIONS - SERVICING AND FAULT FINDING
17