Specifications
STAGE 3
Lay the right rear log as shown in fig. 11.
STAGE 4
Lay the left rear log as shown in fig. 12.
STAGE 5A (LPG ONLY)
For LPG appliances place the front centre log as shown
in fig. 13.
STAGE 5B (NATURAL GAS ONLY)
For natural gas appliances place the front centre log as
shown in fig. 14.
4. OPERATING THE STOVE
SEE USERS SECTION
5. FITTING THE CANOPY
All Exminster gas stoves are supplied with bolt on top
options. The tops are fixed to the stove body using two
M8 nuts and M8 penny washers.
First place the top (either Flat Top or Canopy) on to
the body, locating the studs on the underside of the
canopy through the holes in the top of the stove.
Apply the washer and nut from the inside top of the
stove, whilst the doors are still open, to fix the top and
seal the appliance.
It is important to check that these nuts are tight and
that no spillage can occur, a smear of fire sealing
compound should be used on the washer and nut, to
guarantee the seal. The stove must be checked for
leakage as part of the commissioning by the installer.
6. THE REMOTE CONTROL
Refer to installation instructions supplied with remote
control unit for fitting motor and reciever.
This requires no external power to operate.
The receiver unit can be hidden under or behind the
appliance, ensure that the receiver is located in an area
that has a temerature below 60°C, and that the
customer knows where the receiver is for future battery
replacement.