The Exminster Gas Stove For Natural Gas and LPG INSTALLATION, SERVICING AND USER INSTRUCTIONS This product is for use only in Great Britain and Ireland (GB, IE) These instructions are to be left with the customer, should be read carefully and kept in a safe place. They will be necessary when servicing the appliance.
Contents Commissioning USERS INSTRUCTIONS Welcome to Yeoman Commissioning Data Guarantee Safety Notes Operating the Stove Remote Control (Manual Operation) Twin Rotary Control with Optional Remote Timer Remote Control Ventilation Arrangement of the Fuel Bed 3 4 4 5 5 5 Completing the Installation Appliance Testing Commissioning the Stove Post Installation Checks Servicing and Fault Finding 6 6 7 8 Servicing Instructions Trouble Shooting Short Spares List Service Record INSTALLATION INSTRUCTIONS Techn
Welcome to Yeoman IMPORTANT NOTICE Your new Exminster gas stove is perhaps the most advanced design of modern stoves. Owning such a stove shows appreciation for exceptional quality. If your stove is installed correctly, it will give you many years of excellent service for which it was designed. This appliance must be installed by a qualified installer, we recommend that you have a CORGI registered engineer to install your stove for you.
USERS INSTRUCTIONS 1. COMMISSIONING DATA h) The completion and return of Stovax’s Warranty Registration Card, which is supplied with your stove. This information must be completed and signed by the installation engineer. None of the above restrict your statutory rights.
USERS INSTRUCTIONS 3. SAFETY NOTES The Exminster operates with a permanent pilot light. The pilot light is located in the centre of the burner and is visible through a cut-out in the ceramic matrix. If the Flame Supervision Device Actuating Flame (the Pilot Light) is extinguished either by intention or not, no attempt should be made to re-light until 3 minutes have elapsed.
USERS INSTRUCTIONS 5.1 TIMER REMOTE CONTROL c) Running the stove at low setting 1. Ignite permanent pilot and run stove at “HIGH” setting for a minimum of 10 minutes as shown in Fig. 2. 2. Fig. 6 With the right-hand control knob at the highest setting, rotate in a clock-wise direction to the lowest setting (filled circle). See Fig. 3. Fig. 3 PM164-6 PM164-3 d) Extinguishing the stove back to permanent pilot setting 1.
USERS INSTRUCTIONS Press TIMER again to set the second heating period P2✷ heat on and P2 (heat off) transmitter display, the receiver’s LED must illuminate) For the AUTO or TIMER mode to function correctly, the transmitter must remain within range of the receiver. The transmitter should not be used in very close proximity to the receiver (less than 1m/3ft) as this could, in very rare cases, produce a electronic switching error.
USERS INSTRUCTIONS 7. ARRANGING THE LAYOUT OF THE COALS STAGE 1 Lay the Ceramic Mat on top of the Burner as shown in Fig. 7 making sure that all holes including the small cross lighting holes are not blocked, and that the pilot assembly is not obstructed. Only the ceramic coals supplied with this appliance are to be used. The coals must be laid only as shown on the following pages. Fig. 7 Replacement coals, ceramic and mat are available from your dealer.
USERS INSTRUCTIONS 11. ARRANGING THE LAYOUT STAGE 4 OF THE LOGS Position the top centre matrix as shown in Fig.10, noting that on Natural Gas appliances the Top Matrix is pulled right forward to touch the front matrix, for LPG it should be positioned back from the front matrix supported on the two protruding extensions. Only the ceramic Logs supplied with this appliance are to be used. The Logs must be laid only as shown on the following pages.
USERS INSTRUCTIONS STAGE 4 Lay the left rear log as shown in fig. 15. Fig. 15 PM166-13 STAGE 5A (LPG ONLY) For LPG appliances place the front centre log as shown in fig. 16. Fig. 16 PM166-14 STAGE 5B (NATURAL GAS ONLY) For Natural Gas appliances place the front centre log as shown in fig. 17. Fig.
INSTALLATION INSTRUCTIONS - TECHNICAL SPECIFICATIONS 1. LIST OF COMPONENT PARTS FOR THE EXMINSTER GAS STOVE. 2. DIMENSIONS OF STOVE. Fig. 1 1 No. Stove body complete with burner. COALS LOGS 1 Front Matrix left 1 Rear Centre log 1 Front Matrix right 1 Left Rear log 1 Rear Matrix left 1 Right Rear log 1 Rear Matrix right 1 Centre Front log 1 Top centre Matrix 1 Bag of embers 5 Small Ceramic Coals 1 Large Ceramic Coal 1 Ceramic mat PM166-1 3. 1 No.
INSTALLATION INSTRUCTIONS - SITE REQUIREMENTS 1. FLUE REQUIREMENTS. Please note that all flue systems should be installed in accordance with the flue manufactures recommendations and BS5871:pt.1. The flue which the appliance is to be attached must conform to BS 5440 2000:pt.1. Before the appliance is installed, the flue system or chimney must be inspected and passed as suitable.
INSTALLATION INSTRUCTIONS - INSTALLATION 1. GAS CONNECTION Fig. 3 Before installation, ensure that the local distribution conditions (identification of the type of gas and supply pressure) and the adjustment of the appliance are compatible. It is important to ensure that all pipe work installed is fitted in accordance with BS6891 and is capable of supplying sufficient gas flow and pressure to meet the minimum pressures quoted on page 10 of this manual.
INSTALLATION INSTRUCTIONS - INSTALLATION Fig. 5 Fig. 8 PM166-9 3. ARRANGING THE LAYOUT OF THE LOGS Only the ceramic Logs supplied with this appliance are to be used. The Logs must be laid only as shown on the following pages. PM166-6 Replacement logs and ceramic mat are available from your dealer, but should only be installed by a CORGI registered engineer. STAGE 3 The parts required for the log layout are listed below:- Place the Front left & right Matrices as shown in Fig.
INSTALLATION INSTRUCTIONS - INSTALLATION 4. STAGE 3 Lay the right rear log as shown in fig. 11. OPERATING THE STOVE SEE USERS SECTION Fig. 11 5. FITTING THE CANOPY All Exminster gas stoves are supplied with bolt on top options. The tops are fixed to the stove body using two M8 nuts and M8 penny washers. First place the top (either Flat Top or Canopy) on to the body, locating the studs on the underside of the canopy through the holes in the top of the stove.
INSTALLATION INSTRUCTIONS - COMMISSIONING INSTRUCTIONS 1. COMPLETING THE INSTALLATION 4. Before leaving the appliance connected to the gas supply, the installer is required to visually examine the appliance and flueway to ensure that: THE APPLIANCE MUST NEVER BE OPERATED WITH THE DOOR REMOVED OR GLASS BROKEN. When the coals and matrices have been arranged as shown in section 3, the door(s) must be closed and a good seal achieved, using the supplied washer and nut.
INSTALLATION INSTRUCTIONS - SERVICING AND FAULT FINDING ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS 2. TROUBLE SHOOTING A) The gas pilot will not ignite or stay lit? i) Ensure the gas is turned on at the appliance and the meter/cylinder. ii) Depress the control knob for at least twenty seconds once the pilot is alight to ensure the operation of the safety thermocouple valve. iii) Ensure that the pilot injector is not obstructed or blocked and it is free from any dust or dirt.
SERVICE RECORD 1ST SERVICE 6TH SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Next Service Due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Next Service Due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signed: . . . . . . . . . . . . . . . . . . . . . .
NOTES
YEOMAN STOVES A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, EX2 7LF Tel: 01392 474500 Fax: 01392 219932 www.yeoman-stoves.co.uk Email: yeoman@stovax.