Instruction manual
– 21 –
Const items Functions Contents
(8) Shifter / On
Voltage
Sets speed shift
start input voltage
Adjusting the Level of Shifter Control Starting Voltage
When the voltage is over (or under) the preset value,
the ignition is cut off. With the positive value at which
the engine torque is through, the ignition is cut off
over the preset value and with the negative value the
ignition is cut off under the preset value.
(Example) 2V: Igniting is cut off over 2V. -2V: Ignition
is cut off under 2V.
The setting range covers from -5.00 to 4.96V.
Switching on using the kit harness requires 2.5V.
(9) Comp. RAM
Correction
Adjusts A/F
relating to Ram
pressure
Entered if there is discrepancy of A/F compared with
the vehicle speed.
Can be adjusted within the range of ±10%.
(10) Rev. Limiter
Offset
Corrects revolution
limiter
Can be corrected within a range of -1000 rpm to 0
rpm to existing value of revolution limiter.
(11) Pit Road Limiter For pit load control
Setting of engine
revolution limiter
Set within range of EG revolution range between
2000 and revolution limit rpm.
Only effective in first and second gear.
(12) Gear Ratio 1st
2nd
3rd
4th
5th
6th
Transmission
selection
Transmission selection function
Enter the ratio of each gear (number of wheel teeth/
number of pinion teeth)
(13) Number of teeth
(6th/Wheel)
Enter the number of teeth on the wheel side of the
gear fitted with a sensor (No. of teeth on wheel side
of sixth gear)
(14) VI
(VARIABLE
INTAKE)
VI starts operating.
Determine the
engine speed.
Set within range of EG revolution range between
5000 and revolution limit rpm.
(16) Comp. IDL Idling correction Idling correction function (=Engine brake also
changes)