MyPBX U100 & U200 Installation Guide MyPBX U100 & U200 Installation Guide Version: V1.0 Yeastar Technology Co., Ltd Date: 25th February, 2013 http://www.yeastar.
MyPBX U100 & U200 Installation Guide Contents 1. PREPARATION BEFORE INSTALLATION .................................................................. 3 2. HARDWARE SPECIFICATIONS .............................................................................. 4 2.1 Overview .................................................................................................. 4 2.2 LED Indicators and Ports .............................................................................. 5 2.
MyPBX U100 & U200 Installation Guide About MyPBX U100 & U200 MyPBX U100 is a 1U rack mount model IP PBX for up to 25 concurrent calls and 100 users. Internally, it supports network access to ISDN BRI, PSTN, GSM/UMTS and VoIP. High performance, stability and compatibility, combined with rich functionality make MyPBX U100 perfectly suited for your business communication. MyPBX U200 is a workhorse designed for companies requiring up to 50 concurrent calls and 200 users.
MyPBX U100 & U200 Installation Guide Serial Line PC 1 Mounting ear PC 2 Screws PC 8 8 screws (φ3.0*6mm) for mounting ears Sheet 1 MyPBX U100 & U200 Packing List 2. Hardware Specifications 2.1 Overview Fi gure 2-1 MyPBX U100 Fi gure 2-2 MyPBX U200 http://www.yeastar.
MyPBX U100 & U200 Installation Guide 2.2 LED Indicators and Ports Fi gure 2-3 MyPBX U100 & U200 Front Pa nel Fi gure 2-4 MyPBX U100 & U200 Rea r Pa nel LED Power RUN 1-16 Indication Power status Status Description On The power is switched on. Off The power is switched off. MyPBX status Blinking MyPBX is running properly. FXO port status Not Blinking/Off Red light MyPBX goes wrong. The red light is blinking: the PSTN line hasn’t been Connected.
MyPBX U100 & U200 Installation Guide GSM/ UMTS Red light port The red and green light s are blinking alternately: there status BRI port status The red light is blinking: no SIM card inserted. is an incoming call. The red and green lights are blinking alternately and rapidly: the call is connected and the trunk is in use. Orange light Orange light: indicates the BRI port The orange light is blinking: the BRI line is disconnected. The orange light is on: the BRI line is connected or in use.
MyPBX U100 & U200 Installation Guide Storage Humidity 0%~95% (Non-condensing) Weight 2.1 kg 3. MyPBX U100 & U200 Installation To avoid unexpected accident, personal injury or device damage, please read the following instructions before installing MyPBX U100 & U200. 3.1 Placement Instructions Ambient Temperature: to avoid overheating, please do not run MyPBX U100 & U200 in the place where the ambient temperature is above 122℉ (50℃).
MyPBX U100 & U200 Installation Guide 3.2.2 Connection of FXO/GSM/UMTS/BRI ports MyPBX U100 & U200 supports various outside lines (e.g. FXO, GSM/UMTS, or BRI). Below are the connection instructions of each kind of outside line taking the device installed with 2 FXO ports, 2 GSM ports, and 2 BRI ports as an example. 1. Connection of FXO ports The FXO port could be connected to the PSTN line or the FXS port of a traditional PBX with a phone line. For instance, if No.2 and No.
MyPBX U100 & U200 Installation Guide Fi gure 3-3 Connection of GSM/UMTS ports 3. Connection of BRI ports The BRI port could be connected to the BRI line and the BRI port of a traditional PBX with a BRI RJ45-RJ11 cable. For instance, if No.14 and No.16 connectors are BRI ports, the connection could be depicted as below: Fi gure 3-4 Connection of BRI ports 3.2.3 Connection of FXS ports The FXS port could be connected to an analog phone with a phone line. For instance, if No.6 and No.
MyPBX U100 & U200 Installation Guide Fi gure 3-5 Connection of FXS ports 3.2.4 Power Connection Once users have made sure that device installation, cable connection and power type is correct, please switch on the power. Then MyPBX U200 will start booting. In the meantime, users would see that the ‘POWER’ and ‘RUN’ indicator lights would turn on. Please switch off the power before plugging or unplugging the cables. 3.2.5 Overall Flow Chart Fi gure 3-6 Overall Flow Cha rt http://www.yeastar.
MyPBX U100 & U200 Installation Guide 4. MyPBX U100 & U200 Basic Configurations 4.1 Factory Defaults MyPBX U200 provides web-based configuration interface for administrator and account user. The user can manage the device by log in the web interface. The factory default IP address: LAN: 192.168.5.150; Access path: http://[IP address] User Name: admin; Password: password Default SIP UDP port: 5060 There are 6 extensions set up by default. The user could use these extensions directly, edit or delete them.
MyPBX U100 & U200 Installation Guide Fi gure 4-2 MyPBX Admin Confi gura tion Interfa ce Via the configuration interface, the admin can make all the system configurations, including network settings (LAN, WAN, Firewall, VPN, DDNS, VLAN, etc.); system parameters configuration (system prompts, time zone, password, etc.); internal settings (Web access port, user extension range, business hours, conference room, paging and intercom, music on Hold, etc.
MyPBX U100 & U200 Installation Guide Please note that after changing the IP address of LAN port, MyPBX should be rebooted to make the new changes take effect. 4.4 Extensions Setup and management MyPBX has already set up 6 extensions by defaults which are extension”300-305”. The password is “pincode + extension number”. It’s up to the user to use these default extensions directly or after changing the password. Of course, they could be deleted.
MyPBX U100 & U200 Installation Guide 3. Inbound calls When the user calls the trunk number of the PSTN line, MyPBX would route the call to IVR (the “welcome” prompt) by default. Then the user can dial the extension number following the prompt. 4.