User Manual
Configuration Guide for User Access Level
2
User: The end user access level. Generally, only a few configurations are allowed to be
written and read for access user. The authentication identity for this access level is user.
And the default password is user.
Specification
Access permissions of all configuration items available on Yealink W56P/SIP
VP-T49G/SIP-T48G/T48S/T46G/T46S/T42G/T42S/T41P/T41S/T40P/T29G/T27P/T27G/T23P/T23G
/T21(P) E2/T19(P) E2/CP860 IP phones’ web user interface and phone/handset user interface can
be defined in a fixed WebItemsLevel.cfg file. Each configuration item in the file is formatted as:
ItemName = X
1
X
2
The valid values of X
1
, X
2
include 0, 1, 2 and 3.
X
1
is used for specifying the access level. The access levels: 2 = admin, 1 = var, 0 = user, 3 =
none.
X
2
is used for defining the access permission. 2 means the configuration item is read-only for X
1
and higher access levels, the highest is always writable. 1 means the configuration item is
read-only for X
1
access level, and writable for higher access levels. 0 means the configuration
item is writable for X
1
and higher access levels. 3 means the configuration item is read-only for
X
1
and higher access levels.
The following table lists the possible values of X
1
X
2
and the configuration results with different
access levels:
(W: writable; R: read-only; N: hidden)
Results
Values of X
1
X
2
admin (2)
var (1)
user (0)
0
WR
WR
WR
1
WR
WR
N
2
WR
N
N
3
N
N
N
00
WR
WR
WR
01
WR
WR
R
02
WR
R
R
03
R
R
R
10
WR
WR
N
11
WR
R
N
12
WR
R
N
13
R
R
N