Specifications

Administrators Guide for SIP-T2xP IP Phones
350
Default Value
Blank
Range
Not Applicable
Example
network.802_1x.client_cert_url =
http://192.168.1.10/ client.pem
TR-069
Parameter-
managementserver.enable
Configuration File
<y0000000000xx>.cfg
Description
Enables or disables TR-069 feature on the IP
phone.
Note: If you change this parameter, the IP
phone will reboot to make the change take
effect.
Format
Integer
Default Value
0
Range
0-Disabled
1-Enabled
Example
managementserver.enable = 1
Parameter-
managementserver.username
Configuration File
<y0000000000xx>.cfg
Description
Configures the user name to authenticate
with the ACS. This string is set to the empty
string if no authentication is required.
Note: If you change this parameter, the
phone will reboot to make the change
take effect.
Format
String
Default Value
Blank
Range
Not Applicable
Example
managementserver.username = user1
Parameter-
managementserver.password
Configuration File
<y0000000000xx>.cfg
Description
Configures the password to authenticate