User Manual Part 2
Link CX-24 User’s Manual
Version 1.0 Page 77 February 2004
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit error rate alarm will be generated if the level
of BER is at or above 10^-3, i.e. if bitErrorRate is
equal to or greater than 100000."
::= { link_cx_status 11 }
-- link_cx_test group
rfTxAttenuateTimer OBJECT-TYPE
SYNTAX INTEGER (0..1800)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To temporarily enable Tx attenuation by 40 dB, write the number of
seconds to this timer. When the timer counts down to 0, Tx attenuation
will return to its normal unattenuated state. Writing to this timer
has no effect if rfTxAttenuateControl is set to enable because in
that case the transmitter is already attenuated."
::= { link_cx_test 1 }
-- link_cx_reboot group
softwareVersionBank1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software version in bank one."
::= { link_cx_reboot 1 }
softwareVersionBank2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software version in bank two."
::= { link_cx_reboot 2 }
bootedUsingBankNumber OBJECT-TYPE
SYNTAX INTEGER {
bankOne(1),
bankTwo(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software bank from which the unit booted."
::= { link_cx_reboot 3 }
bootUsingBankNumber OBJECT-TYPE
SYNTAX INTEGER {